Chapter 2 

Installing the TB130 DC Output UPS 

Your Touchstone device may be shipped with a standard power adapter, or it may be 

shipped with a TB130 DC Output UPS. 
1.

 

If your Touchstone device was shipped with a TB130 DC Output UPS, skip to step 3. 

2.

 

If your Touchstone device was shipped with a standard power adapter, disconnect the 

standard power adapter from the power adapter connector on the back of your 

Touchstone device. 

  Note

: Disconnecting the standard power adapter immediately disconnects all active 

phone calls and data connections. 

3.

 

Locate the custom end of the TB130 as shown in the following photo. 

 

4.

 

Orient the white tab on the custom end of the TB130 with the slot next to the power 

connector on the back of your Touchstone device. 

5.

 

Insert the custom end of the TB130 into the power adapter connector on the back of 

your Touchstone device. Make sure the plug is fully inserted before continuing. 

6.

 

Double-check that the AC power cord is securely connected to the body of the battery 

unit. 

7.

 

Insert the AC plug into a standard power outlet. 

As long as all of the connections for the TB130 are securely made, the TB130 provides power 

to your Touchstone device, and charges the battery. The LED on the TB130 is steady green to 

show AC power is functioning normally. See "LED Behavior" below for more information. 

Summary of Contents for Touchstone TB130

Page 1: ...Touchstone TB130 DC Output UPS User Guide Release 2 5 STANDARD 1 0 August 2017 August 2017...

Page 2: ...all trademarks of ARRIS Enterprises LLC Other trademarks and trade names may be used in this document to refer to either the entities claiming the marks or the names of their products ARRIS disclaims...

Page 3: ...ses LLC All Rights Reserved 3 Table of Contents 1 Product Overview 4 2 Installing the TB130 DC Output UPS 5 3 Wall Mounting the TB130 6 4 LED Behavior 8 5 Testing and Troubleshooting the TB130 9 6 Saf...

Page 4: ...ower supply backed by a rechargeable lithium ion battery The TB130 DC Output UPS is an optional product that may be offered with designated ARRIS modem products such as the TM3402 Telephony Modem The...

Page 5: ...ts all active phone calls and data connections 3 Locate the custom end of the TB130 as shown in the following photo 4 Orient the white tab on the custom end of the TB130 with the slot next to the powe...

Page 6: ...o wall mount the TB130 Requirements Two screws 10 x 1 5in wood screws or equivalent or drywall anchors Pencil Ruler Drill with 1 8in 3 5mm bit for wood screws if using drywall anchors see the packagin...

Page 7: ...1 0 August 2017 Touchstone TB130 DC Output UPS User Guide 2017 ARRIS Enterprises LLC All Rights Reserved 7 6 Align the mounting holes on the TB130 shown below with the screws and slide the device ont...

Page 8: ...ng green Normal battery operation Running on battery power Solid red Battery or Charging fault AC power is present Slow pulsing red Battery or Charging fault Running on battery power Off No battery ba...

Page 9: ...es power to the modem If the LED turns green the problem was transient The modem may download new firmware to the TB130 if available 3 Disconnect AC power and allow the device to run on battery power...

Page 10: ...or near a swimming pool etc to avoid risk of electrocution The product shall be cleaned using only a damp lint free cloth No solvents or cleaning agents shall be used Do not use spray cleaners or aer...

Page 11: ...he receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dea...

Page 12: ...Corporate Headquarters ARRIS Suwanee Georgia 30024 USA T 1 678 473 2000 F 1 678 473 8470 www arris com...

Reviews: