background image

Chapter 2

Testing and Troubleshooting the TB130

 

 

Release 2.5 STANDARD 1.0    August 2017 

Touchstone TB130 DC Output UPS User Guide 

© 2017 ARRIS Enterprises LLC. All Rights Reserved. 

 

 

Testing and Troubleshooting the TB130 

If the LED is red, there is an internal problem with the TB130. Follow these steps to test the 

backup system. 
1.

 

Pick a time when you do not expect phone calls or need to use the broadband Internet 

connection. This test may remove power to the Telephony Modem or Telephony 

Gateway. 

2.

 

Disconnect the DC power cable from the Telephony Modem or Telephony Gateway, then 

re-insert it. This removes power to the modem. If the LED turns green, the problem was 

transient. The modem may download new firmware to the TB130, if available. 

3.

 

Disconnect AC power and allow the device to run on battery power. The device shuts 

down data services to preserve the battery for phone calls. Depending on the battery 

condition and the connected device, it may take up to 9 hours to completely discharge 

the battery. 

4.

 

Watch for the TB130 

Status

 LED, and the 

Power

 LED on the Telephony Modem or 

Telephony Gateway, to turn off. 

5.

 

Wait one more minute, then reconnect AC power. If the TB130 

Status

 LED is still red, 

there is a problem with either the battery itself or the internal charging system. Replace 

the TB130, and recycle the old unit. 

  Note

: The TB130 battery should last 6 to 8 years under normal operating conditions. 

 

Summary of Contents for Touchstone TB130

Page 1: ...Touchstone TB130 DC Output UPS User Guide Release 2 5 STANDARD 1 0 August 2017 August 2017...

Page 2: ...all trademarks of ARRIS Enterprises LLC Other trademarks and trade names may be used in this document to refer to either the entities claiming the marks or the names of their products ARRIS disclaims...

Page 3: ...ses LLC All Rights Reserved 3 Table of Contents 1 Product Overview 4 2 Installing the TB130 DC Output UPS 5 3 Wall Mounting the TB130 6 4 LED Behavior 8 5 Testing and Troubleshooting the TB130 9 6 Saf...

Page 4: ...ower supply backed by a rechargeable lithium ion battery The TB130 DC Output UPS is an optional product that may be offered with designated ARRIS modem products such as the TM3402 Telephony Modem The...

Page 5: ...ts all active phone calls and data connections 3 Locate the custom end of the TB130 as shown in the following photo 4 Orient the white tab on the custom end of the TB130 with the slot next to the powe...

Page 6: ...o wall mount the TB130 Requirements Two screws 10 x 1 5in wood screws or equivalent or drywall anchors Pencil Ruler Drill with 1 8in 3 5mm bit for wood screws if using drywall anchors see the packagin...

Page 7: ...1 0 August 2017 Touchstone TB130 DC Output UPS User Guide 2017 ARRIS Enterprises LLC All Rights Reserved 7 6 Align the mounting holes on the TB130 shown below with the screws and slide the device ont...

Page 8: ...ng green Normal battery operation Running on battery power Solid red Battery or Charging fault AC power is present Slow pulsing red Battery or Charging fault Running on battery power Off No battery ba...

Page 9: ...es power to the modem If the LED turns green the problem was transient The modem may download new firmware to the TB130 if available 3 Disconnect AC power and allow the device to run on battery power...

Page 10: ...or near a swimming pool etc to avoid risk of electrocution The product shall be cleaned using only a damp lint free cloth No solvents or cleaning agents shall be used Do not use spray cleaners or aer...

Page 11: ...he receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dea...

Page 12: ...Corporate Headquarters ARRIS Suwanee Georgia 30024 USA T 1 678 473 2000 F 1 678 473 8470 www arris com...

Reviews: