CHAPTER 3 - Safety measures
FlexiBowl® - Models 200 - 350 - 500 - 650 - 800
3.2
Noise
The noise was measured in compliance with the provisions of UNI EN 11200 and UNI EN ISO 3746. During the operating cycles,
staff are exposed to a noise level of 90 dB.
The actual noise level during operation of the machine installed on site in a production process is different from the one measured
because the noise is affected by a number of factors, such as:
•
type and characteristics of the site;
•
type of machine that Flexibowl® is installed on;
•
other adjacent machines in operation.
OBLIGATION!
It is mandatory to use the appropriate personal protective equipment.
3.3
Vibrations
The vibrations produced by the machine, based on its operating mode, are not dangerous to the health of the operators.
CAUTION!
Excessive vibrations can only be caused by a mechanical breakdown that must immediately be reported and fixed,
so as not to undermine the safety of the line or of the operators.
3.4
Electromagnetic compatibility
The supplied machine contains electronic components subject to the regulations on Electromagnetic Compatibility, affected by
conducted and radiated emissions.
The emission values are within the regulatory requirements thanks to the use of components that comply with the Electromagnetic
Compatibility directive, suitable connections and installation of filters where necessary.
Thus the machine complies with the Electromagnetic Compatibility (EMC) directive.
CAUTION!
Any non-compliant maintenance work carried out on the electrical equipment or incorrect replacement of
components may undermine the efficiency of the implemented solutions.