CHAPTER 6 - Controls and use
57
Instructions for use and warnings
6.2.4.2
Shake
Pos.
Item
Description
1
Shake
It shows the window to set the Shake command parameters.
Note: to execute the movement command, press the Test Shake button
2
Acceleration
Acceleration used for each subsequent Shake command.
3
Deceleration
Deceleration used for each subsequent Shake command.
4
Speed
Speed, in RPM, at which to shake the Flexibowl® at each subsequent shake
command.
5
CCW Angle
Counterclockwise angle the Flexibowl® moves for each shake at subsequent
shake command.
6
CW Angle
Clockwise angle the Flexibowl® moves for each shake at subsequent shake
command.
7
Count
Number of Shake command.
Example: sh_count=3 means that the Flexibowl® will move counterclockwise at
an angle of ccw_angle, clockwise at an angle of cw_angle, repeated 3 times.
8
Information
Information regarding the parameter.
9
Test Shake
It performs the Shake movement with the selected parameters.