58
CHAPTER 6 - Controls and use
FlexiBowl® - Models 200 - 350 - 500 - 650 - 800
6.2.4.3
Option
Pos.
Item
Description
1
Option
It shows the main window regarding the Flexibowl® general options (Flip, Blow,
Backlight, etc.)
2
Flip Count
Number of ON/OFF cycles that the Flip will perform at each subsequent Flip
command.
3
Flip Delay
Time, in milliseconds, between an ON and an OFF of the Flip at each subsequent
Flip command.
4
Blow Time
Air Blow time, in milliseconds.
5
Light
Turn the backlight on/off.
6
Enable Digital I/O
Enable the option to command the Flexibowl® via I/O.
Note: The Flexibowl® must be restarted to apply.
7
Test Flip
It performs a Flip command
with the selected parameters
.
8
Test Blow
It performs an Air Blow command with the selected parameters.
8
Information
Information regarding the parameter.
10
Send Parameters To Flexibowl®
It saves the command parameters set in the Flexibowl® user interface.
11
Save To File
It saves the command parameters set in the Flexibowl® user interface in a file.
12
Load From File
It loads the command parameters from a previously saved file.