CHAPTER 7 - Maintenance
91
Instructions for use and warnings
7.4
Troubleshooting
No.
Problem
Solution
1
The status LED (Ready/Fault) is red.
•
If the Flexibowl®
is working, check operation of the
LED or the mechanical relay inside the interface.
•
Check the condition of the fuse inside the power input
module and replace it if necessary.
•
Check that no parts prevent free movement of the
Rotary Disc
Note: if the problem persists, contact ARS S.r.l.
2
The Flexibowl® vibrates/oscillates excessively.
•
Check that the screws are tightened properly.
•
Check if the load of Flexibowl® is within the permitted
parameters based on the model.
•
Try to decrease the movement parameters
(acceleration, deceleration, speed)
Note: if the problem persists, contact ARS S.r.l.
3
The status LED (Ready/Fault) is off.
•
Check that the power supply is correct and
working.
•
Check the condition of the fuses inside the
interface board and replace it if necessary.
Note: if the problem persists, contact ARS S.r.l.
4
The Flip does not work.
•
Check that the screen displays the correct pressure
•
Check the air pressure inside the air supply system
control panel.
•
Check the condition of the pressure regulator.
•
Check that the power supply is correct and
working.
•
Check that the valves work properly.
•
Make sure the valve relay inside the interface is
working properly.
•
Check the condition of the fuse inside the interface
and replace it if necessary.
Note: if the problem persists, contact ARS S.r.l.
5
The Air Blow does not work.
•
Check that the screen displays the correct pressure
•
Check the air pressure inside the air supply system
control panel.
•
Check the condition of the pressure regulator.
•
Check that the power supply is correct and
working.
•
Check that the valves work properly.
•
Make sure the valve relay inside the interface is
working properly.
•
Check the condition of the fuse inside the interface
and replace it if necessary.
Note: if the problem persists, contact ARS S.r.l.