WL 150 DIM / USER MANUAL / ENGLISH

5

02

PRODUCT DESCRIPTION

DEFAULT SETTINGS

2.1  DEFAULT DMX CHANNELS

The DMX channels in a standard setting

DMX

FUNCTION DESCRIPTION

FUNCTION

1

Dimming 0–100%

active

2

0% - halogen dimming, 1-99% - Strobo, 100% - LED dimming

inactive

The luminaire is by default set as one channel device with active working light func-

tion (worklight). Only the intensity is controlled!

According to the above DMX table it is apparent that the luminaire may also have two 

DMX channels. The second DMX channel may be activated by the user himself or the 

user can ask his supplier to activate the second DMX channel already when purchasing 

the luminaire.

2.2  WORKLIGHT FUNCTION

If the Worklight function is active (default setting), then the luminaire will light up to 

100 % when connected to the electric power mains. ATTENTION! For a period of 1-2 

seconds when connected to the 230V electric power mains the luminaire does not re-

spond (charging of the electronics) and then gently starts up in a time of 1 second. If 

you want to dim the luminaire continuously, then connect to the input XLR connector 

the DMX signal. As soon as the luminaire detects the DMX signal then it turns off (if no 

DMX values available) or changes to the set level, which is sent to by an external DMX 

controller. From this moment on you can continuously dim the luminaire by the external 

DMX controller from 0-100 %. If you interrupt the DMX signal, or you switch it off, then 

the luminaire will start again to behave like an ordinary unregulated working light.

If the Worklight function is switched off, then the luminaire will do nothing after connec-

tion to the electric power mains. It is waiting to get some value on its DMX channel and 

according to this value it responds. In practice this means that without a source of DMX 

signal the luminaire can not be lighted up.

Summary of Contents for WL 150 DIM

Page 1: ...WL 150 DIM USER MANUAL THEATRE AND STAGE LUMINAIRE ENGLISH VERSION 02 2017...

Page 2: ......

Page 3: ...to you the new working and stage studio floodlight WL 150 DIM of the company Art Lighting Production s r o Ltd Please read this operation manual carefully Non observance of the operation manual may c...

Page 4: ...t we can adjust Color rendering index CRI 80 Max surface temperature 65 C Min distance from the surrounding objects 0 5 m Dimension 380 x 240 x 150 mm Enclosure protection class IP 40 Weight 4 6 kg Ma...

Page 5: ...N 4 2 DEFAULT SETTINGS 5 2 1 DEFAULT DMX CHANNELS 5 2 2 WORKLIGHT FUNCTION 5 2 3 STROBO MODE 6 2 4 WORKLIGHT MODE 6 2 5 LIGHT INTENSITY BLOCKED DMX INPUT 7 2 6 SERVICE MENU 8 3 OTHER INSTRUCTIONS 8 4...

Page 6: ...ER MANUAL ENGLISH 4 PRODUCT DESCRIPTION 01 1 Bracket for hanging lamps 2 Protecting light diffusion plate 3 DMX INPUT 4 DMX OUTPUT 5 Numeric display 6 Status light DMX LINK 7 Control buttons UP DOWN 3...

Page 7: ...a period of 1 2 seconds when connected to the 230V electric power mains the luminaire does not re spond charging of the electronics and then gently starts up in a time of 1 second If you want to dim t...

Page 8: ...tarts flashing 5 When pressing the button UP you will switch the 0 to 1 and the STROBO function 2 channel is activated The symbol has changed to 6 c 1 the second DMX channel STROBO is active 6 Back to...

Page 9: ...ion should be used only when you do not want to use the Worklight func tion The input DMX signal is blocked after selection of this function 1 Using the buttons UP and DOWN set the DMX address 1 2 Wai...

Page 10: ...inaire The luminaire is not designed for use in outdoor or wet areas The connection and putting into operation of the fixture should be made only by qualified electrical technicians by course of the r...

Page 11: ...aining The fixture may be operated by trained per sons according to the regulation 50 78 Col When using the fixture the instructions of this Operation manual have to be observed Operating conditions I...

Page 12: ...pment in a damp or wet environment Do not use the equipment in an environment with high operating tempera tures above 40 C Do not look at a short distance directly into the light if the equipment is s...

Page 13: ......

Page 14: ...ghting Production s r o Komensk ho 427 664 53 jezd u Brna esk republika Tel 420 544 224 312 info artlighting cz www artlighting cz 2017 Art Lighting Production s r o Graphic design v2atelier com WL 15...