27
5.6. B3D Controller
5.6.1. Overview
B3D controller is an implemented B3D system component intended for hardware integration of B3D
system with elements of other Access Control Systems. B3D controller can provide communication with
the following components of Access Control Systems:
Card readers (proximity-readers, smart-card readers, magnetic card readers, barcode
readers, and etc.) via Wiegand in interface of up to 64 bit
Door controllers via Wiegand out interface of up to 64 bit
Actuating mechanism (electro-mechanical or magnetic lock, turnstile, gate, barrier, and
etc.) via dry out contact
FIG 26. B3D Controller’s connectors layout.
LEFT CONNECTOR
RIGHT CONNECTOR
Pinout
Description
Pinout
Description
N1
Relay 1 output (common)
D0
in
D0 of the Card reader
NC1
Relay 1 Normal Closed
Green*
To “Green” contact of the Card
reader
NO1
Relay 1 Normal Opened
Hold*
To “Hold” contact of the
Card reader
Tamper
NC output, opens when 3D camera
is being unattached.
GND
Ground
Exit
button
Switches relay when closing to GND GND
Ground
Auxiliary* Reserved
D0
out
D0 of the Door controller
N2*
Relay 2 output (common)
D1
in
D1 of the Card reader
NC2*
Relay 2 Normal Closed
Red*
To “Red” contact of the Card reader
NO2*
Relay 2 Normal Opened
Buzzer*
To “Buzzer” contact of the Card
reader