Page 9
FiberLink 5200 Series User’s Manual
FIberLink 5200 Series
Note: when using the two-fiber version, you must connect transmitter “A” Optical
1 to receiver “B” Optical 1 and transmitter “A” Optical 2 to receiver “B” Optical 2.
7) Connect the Universal Power Supply to the transmitter and receiver units .
For box versions using DC power, please refer to figure 1 .
8) When power is applied, the green POWER LED should illuminate, indicating the
presence of operating power . The audio, and data LEDs will give an indication as
described in the Indicator LED’s and Alarm Circuitry section of this manual .
9) The system should now be operational .
Note: The Rack Card version has an additional red LED for indicating the presence of an alarm
condition (loss of signal). Refer to Indicator LED’s and Alarm Circuitry sections of this manual.
Figure 1:
Power Connector
DC Input Polarity
9-24 Volts
AC or DC
(+) Positive
( - ) Negative
Installation Instructions (cont.)
The transmitting element in the FiberLink 5200 transmitter
unit contains a solid state Laser Diode located in the optical
connector. This device emits invisible infrared electromag-
netic radiation which can be harmful to human eyes. The
radiation from this optical connector, if viewed at close
range with no fiber optic cable connected to the optical
connector, may be sufficient intensity to cause
instantaneous damage to the retina of the eye. Direct
viewing of this radiation should be avoided at all times!
Installation Instructions