15
NOTE: When power is turned on, your spa is automatically pro-
grammed to start circulating water through the circulation pump.
Each pump and/or blower will come on consecutively for approxi-
mately 1 minute to automatically purge the system. Adjust your tem-
perature by pressing the up button on your touch pad until the de-
sired temperature is displayed. This setting will allow your spa to
heat to the set temperature.
DANGER: RISK OF ELECTRICAL SHOCK
If the GFCI breaker fails to operate as described, there is a possibility of an
electrical shock if the spa is used. Shut off the power at the main electrical
service panel until the source of the problem has been identified and cor
-
rected by a licensed electrician or qualified spa technician.
PRIMING THE PUMP
1) Turn off power at electrical service panel.
2) Locate and loosen one of the pump union on each pump by turning it
counterclockwise one half of one turn.
3) Allow air to escape from fittings. When a steady stream of water flows
from the pump union, close it by turning it clockwise until tight.
4) Turn on power at electrical service panel.
5) Check once more to make sure that water is flowing from the jets during
auto purge. If so, continue. If no water is coming from your spa jets, please
call your Artesian dealer for further assistance.
CAUTION: If water is not noticeably coming from your spa jets during
the automatic purge, turn on the high speed pump. If water is still not
coming from the jets, the pump needs to be manually primed, follow-
ing the steps below.
WATER PREPARATION
NOTE:
Before putting your new spa into operation, understand
that preparing your new water is an important part of maintenance.
Failure to properly prepare your water can result in substantially de-
creasing the life of the components and may void your warranty in
severe cases. Your Artesian dealer should have a start-up and main-
tenance kit available for you when you receive your spa.
SPA START-UP