BIOS
ATCA-7360 Installation and Use (6806800J07S
)
130
4.12.4.7 Correctable Memory Log Disabled
This event is generated from the runtime error logging module. It is logged when the
Correctable Memory Error logging limit for the DIMM is reached. No further error events for
this DIMM are logged.
4.12.4.8 Log Area Reset/Cleared
This log entry is the first entry in the SMBIOS log.
Table 4-42 Correctable Memory Log Disabled Event Format
Offset
Name
Format
Description
00h
Event Type
BYTE
Event Type = 01h
01h
Length
BYTE
always 0Ch
02h-07h
Date/Time Fields
BYTE
These fields contain the BCD
representation of the date and time
08h-0Bh
Memory Information
UINT32
OEM extension
Table 4-43 Memory Information Definition
Bit
Description
0-7
reserved
8-15
DIMM number per Channel 0..1
16-23
DIMM channel 0..2
24-31
CPU Socket 0..1
Table 4-44 Log Area Reset/Cleared Event Format
Offset
Name
Format
Description
00h
Event Type
BYTE
Event Type = 16h
01h
Length
BYTE
always 08h
02h-07h
Date/Time Fields
BYTE
These fields contain the BCD
representation of the date and time
Summary of Contents for ATCA-7360
Page 1: ...ATCA 7360 Installation and Use P N 6806800J07S May 2016...
Page 26: ...ATCA 7360 Installation and Use 6806800J07S About this Manual 26 About this Manual...
Page 36: ...ATCA 7360 Installation and Use 6806800J07S Sicherheitshinweise 36...
Page 43: ...Introduction ATCA 7360 Installation and Use 6806800J07S 43...
Page 44: ...Introduction ATCA 7360 Installation and Use 6806800J07S 44...
Page 66: ...Installation ATCA 7360 Installation and Use 6806800J07S 66...
Page 258: ...Supported IPMI Commands ATCA 7360 Installation and Use 6806800J07S 258...
Page 284: ...Replacing the Battery ATCA 7360 Installation and Use 6806800J07S 284...
Page 287: ......