BIOS
ATCA-7360 Installation and Use (6806800J07S)
89
4.2.2
Default Access Parameters
By default, the blade can be accessed using the serial interface COM1. By default, this interface
is accessible using a RJ-45 connector at the blade's faceplate.
A NULL-Modem cable is available as accessory kit for the blade. It converts the RJ-45 connector
to a standard DSUB connector which can be connected to a remote terminal. The following
communication parameters are used, by default:
Baud rate: 9600
Flow control: None
VT-100
8 data bits
No parity
1 stop bit
4.2.3
Connecting to the Blade
Procedure
To connect to the blade using the serial console redirect feature:
1. Configure terminal to communicate using the same parameters as in BIOS setup.
2. Connect terminal to NULL-modem cable.
3. Connect NULL-modem cable to COM port of the blade.
4. Start up blade.
4.3
Changing Configuration Settings
When the system is switched on or rebooted, the presence and functionality of the system
components is tested by Power-On Self-Test (POST).
Summary of Contents for ATCA-7360
Page 1: ...ATCA 7360 Installation and Use P N 6806800J07S May 2016...
Page 26: ...ATCA 7360 Installation and Use 6806800J07S About this Manual 26 About this Manual...
Page 36: ...ATCA 7360 Installation and Use 6806800J07S Sicherheitshinweise 36...
Page 43: ...Introduction ATCA 7360 Installation and Use 6806800J07S 43...
Page 44: ...Introduction ATCA 7360 Installation and Use 6806800J07S 44...
Page 66: ...Installation ATCA 7360 Installation and Use 6806800J07S 66...
Page 258: ...Supported IPMI Commands ATCA 7360 Installation and Use 6806800J07S 258...
Page 284: ...Replacing the Battery ATCA 7360 Installation and Use 6806800J07S 284...
Page 287: ......