Supported IPMI Commands
ATCA-7360 Installation and Use (6806800J07S)
251
8.4.14 Reset IPMC Command
The Reset IPMC command allows the payload to reset the IPMC over the KCS host interface.
8.4.15 Hang IPMC Command
The IPMC provides a way to test the watchdog timer support by implementing the Hang IPMC
command, which simulates firmware hanging by entering an endless loop.
Table 8-39 Reset IPMC Command
Type Byte
Data
Field
Request Data
1:3
PPS IANA Private Enterprise ID
0x00400A = 16394 (Pigeon Point Systems)
LSB Byte first: byte 1 = 0A, byte 2 = 40, byte 3 = 00
4
Reset Type Code
0x00: Cold IPMC reset to the current mode
0x01: Cold IPMC reset to the Normal mode
0x02: Cold IPMC reset to the Standalone mode, for a
description refer to
0x03: Cold IPMC reset to the Manual Standalone mode, for
a description refer to
0x04: Reset the IPMC and enter Upgrade mode
Response Data
1
Completion Code
2:4
PPS IANA Private Enterprise ID
0x00400A = 16394 (Pigeon Point Systems)
LSB Byte first: byte 2 = 0A, byte 3 = 40, byte 4 = 00
Table 8-40 Hang IPMC Command
Type Byte
Data
Field
Request Data
1:3
PPS IANA Private Enterprise ID
0x00400A = 16394 (Pigeon Point Systems)
LSB Byte first: byte 1 = 0A, byte 2 = 40, byte 3 = 00
Response Data
1
Completion Code
Summary of Contents for ATCA-7360
Page 1: ...ATCA 7360 Installation and Use P N 6806800J07S May 2016...
Page 26: ...ATCA 7360 Installation and Use 6806800J07S About this Manual 26 About this Manual...
Page 36: ...ATCA 7360 Installation and Use 6806800J07S Sicherheitshinweise 36...
Page 43: ...Introduction ATCA 7360 Installation and Use 6806800J07S 43...
Page 44: ...Introduction ATCA 7360 Installation and Use 6806800J07S 44...
Page 66: ...Installation ATCA 7360 Installation and Use 6806800J07S 66...
Page 258: ...Supported IPMI Commands ATCA 7360 Installation and Use 6806800J07S 258...
Page 284: ...Replacing the Battery ATCA 7360 Installation and Use 6806800J07S 284...
Page 287: ......