Installation
ATCA-7360 Installation and Use (6806800J07S)
47
Table 2-1 Environmental Requirements
Requirement
Operating
Non-Operating
Temperature
Normal Operation: +5 °C (41 °F) to +40
°C (104 °F) according to Telcordia GR-
63-CORE (NEBS) and ETSI EN 300 019-
1-3, Class 3.1
Exceptional Operation: -5 °C (23 °F) to
+55 °C (131 °F) according to Telcordia
GR-63-CORE (NEBS)
Note: This exceeds ETSI EN 300 019-1-
3, Class 3.1E requirements (-5°C to
+45°C)
-40 °C (-40 °F) to +70 °C (158 °F)
according to Telcordia GR-63-CORE
(NEBS) and ETSI EN 300 019-1-2, Class
2.3
Note: This exceeds ETSI EN 300 019-1-
1, Class 1.2 requirements (storage
from -25 °C to +55 °C
Note: This may be further limited by
installed accessories.
Temp. Change
+/- 0.25 °C/min according to Telcordia
GR-63-CORE
+/- 0.25 °C/min
Rel. Humidity
Normal Operation: 5%rH to 85%rh non-
condensing
Exceptional Operation: 5%rH to 90%rh
non-condensing
According to Telcordia GR-63-CORE
(NEBS) and EN 300 019-1-3, Classes 3.1
and 3.1E
5% to 95% non-condensing according
to Telcordia GR-63-CORE (NEBS) and
EN 300 019-1-1, Classes 1.2 and 2.3
Vibration
1g from 5 to 200Hz and back to 5Hz at
a rate of 0.25 octave/minute
(according to Telcordia GR-63-core)
5-20 Hz at 0.01 g
2
/Hz (according to
Telcordia GR-63-core and ETSI EN 300
019-2-2)
20-200 Hz at -3 dB/octave Hz
(according to Telcordia GR-63-core
and ETSI EN 300 019-2-2)
Random 5-20Hz at 1 m
2
/s
3
Random 20-200Hz at 3 m
2
/s
3
Shock
Half-sine, 11 ms, 30 m/s
2
Blade level packaging
Half-sine, 6 ms at 180 m/s
2
Free Fall
-
1.2 m/ packaged (according to ETSI
300 019-2-2)
100 mm unpackaged (according to
Telcordia GR-63-core)
Summary of Contents for ATCA-7360
Page 1: ...ATCA 7360 Installation and Use P N 6806800J07S May 2016...
Page 26: ...ATCA 7360 Installation and Use 6806800J07S About this Manual 26 About this Manual...
Page 36: ...ATCA 7360 Installation and Use 6806800J07S Sicherheitshinweise 36...
Page 43: ...Introduction ATCA 7360 Installation and Use 6806800J07S 43...
Page 44: ...Introduction ATCA 7360 Installation and Use 6806800J07S 44...
Page 66: ...Installation ATCA 7360 Installation and Use 6806800J07S 66...
Page 258: ...Supported IPMI Commands ATCA 7360 Installation and Use 6806800J07S 258...
Page 284: ...Replacing the Battery ATCA 7360 Installation and Use 6806800J07S 284...
Page 287: ......