ARTEX PRODUCTS / ACR ELECTRONICS, INC
DESCRIPTION, OPERATION, INSTALLATION AND MAINTENANCE MANUAL
ELT 345 (P/N: A3-06-2880)
Page 12 of 58
25-62-35
SUBTASK 25-62-35-990-003
C.
RTCA DO-160G Compliance
1)
DO-160G Environmental Categories:
[C1X]BC[DO-204a][S(C)]XRXXXSZZAZ[ZCX][DO-204a]M[XXXXXX][XXXX]XXX
2)
The DO-160G environmental categories breakdown is detailed in Table 1.
CAT
SECTION
DESCRIPTION
COMMENTS
C1
4.0
Temperature/Altitude
X
4.5.5
In-Flight Loss of Cooling
Not Applicable
B
5.0
Temperature Variation
B = 5°C/min
C
6.0
Humidity
10 Day Test
DO-204A
7.0
Operational Shocks and
Crash Safety
Tested to RTCA DO-204A Requirements
[S(C)]
8.0
Vibration
X
9.0
Explosion Atmosphere
Test
Not Applicable
R
10.0
Waterproofness
Continuous Stream
X
11.0
Fluid Susceptibility
Not Applicable
X
12.0
Sand and Dust
Not Applicable
X
13.0
Fungus Resistance Test
Not Applicable
S
14.0
Salt Fog
Z
15.0
Magnetic Effect Test
Z
16.0
Power Input Test
A
17.0
Voltage Spikes
Z
18.0
AF Susceptibility
ZCX
19.0
Induced Signal
Susceptibility
DO-204A
20.0
RF Susceptibility
Tested to RTCA DO-204A Requirements
M
21.0
RF Emissions
[XXXXXX]
22.0
Lightning Induced
Transient Susceptibility
Not Applicable
[XXXX]
23.0
Lightning Direct Effects
Not Applicable
X
24.0
Icing Test
Not Applicable
X
25.0
Electrostatic Discharge
Test
X
26.0
Fire, Flammability Test
Fire Resistance ED-62A Optional for ELT(AF)
Table 1 Environmental Categories