ARTEX PRODUCTS / ACR ELECTRONICS, INC
DESCRIPTION, OPERATION, INSTALLATION AND MAINTENANCE MANUAL
ELT 345 (P/N: A3-06-2880)
Page 33 of 58
25-62-35
SUBTASK 25-62-35-810-002
B.
Troubleshooting
SYMPTOM
PROBABLE CAUSE
POSSIBLE SOLUTION
Remote switch LED always on
(steady)
Improper wiring
Verify wiring
Short circuit
Verify integrity of all crimp and
solder connections
ELT will not turn off
Turn ELT “OFF” using control switch – If ELT turns off:
Defective remote switch harness
reset circuit wiring
Check wiring continuity and repair
as necessary
Defective remote switch
Replace remote switch
If ELT does not turn “OFF” using control switch:
ELT defective
Remove battery pack to disable ELT
and return ELT to factory for
servicing
Flash Errors
Please Refer to Table 6 Self-test Error Codes
Table 7 ELT Troubleshooting Guide