CE-LABELLING

8.1 CE-labelling

As an electric device the DPC200 falls within the scope of the directive 2004/108/EG  
(EMV-directive). In the scope of the EMV-directive the following norms were applied:

DIN EN 61000-6-2:2006-03
correction 1:2011-06

Electromagnetic compatibility (EMC) - Part 6-2: Generic 
standards - Immunity for industrial environments

DIN EN 61000-6-3:2011-09

Electromagnetic compatibility (EMC) - Part 6-3: Generic 
standards - Emission standard for residential, commer-
cial and light industrial environments

You can order the Declaration of Conformity at:

Arthur Grillo GmbH

Am Sandbach 7
40878 Ratingen

Phone: 0 21 02 - 47 10 22

Fax: 0 21 02 - 47 58 82

E-mail: info@grillo-messgeraete.de

Summary of Contents for DA2000 Series

Page 1: ...Installation and operation manual Differential pressure manometer DA2000 series Doc no DA2000 01 issue 02 2016 ...

Page 2: ...e de www sensor store de 02 2016 DA2000_001 This documentation including all parts is protected by copyright Any utili sation or modification other than permissible under the strict limitations of copyright law is prohibited and liable to prosecution without the approval of the Arthur Grillo GmbH This applies in particular to duplications trans lations microfilming and storage and processing in el...

Page 3: ... and symbols 1 3 General notes 2 Product description 2 1 Intended use 2 2 Functional description 3 Installation 3 1 Dimensions 3 1 1 DA2000 DA2000 A 3 1 2 DA2000 K 3 1 3 DA2000 series in IP66 protective housing 4 Electrical connection 5 Maintenance 6 Warranty 7 Disposal 8 Specifications 8 1 CE labelling 04 04 04 04 05 05 05 05 06 06 07 08 09 10 10 10 11 12 ...

Page 4: ...al damage or minor or moderate bodily injuries CAUTION 1 2 Used pictograms and symbols In this manual the following symbols are used General hazard symbol dan ger warning caution Signal word for important information regarding the product which needs to be specifically pointed out NOTICE Hazard word Type of hazard Hazard source Hazard prevention 1 3 General notes This manual contains information f...

Page 5: ... are low pressure indicator A soft silicone diaphragm is used as sensor Under the influence of the differential pressure the diaphragm displaces a measuring spring until the spring force compensates pressure pushing on the diaphragm The deflection is transferred to the display via a pointer engine To meet your needs we offer the DA2000s with different measuring ranges and optional additional funct...

Page 6: ...e environment has to fulfil the ambient climatic conditions as given in the technical data 3 1 Dimensions All dimensions in mm 3 1 1 DA2000 DA2000 A Wall mounting DA2000 Wall mounting DA2000 A Material damage Read the manual carefully before installation and operation Only experienced stuff may connect the device and bring it into operation CAUTION The device is position depended The DA2000 must b...

Page 7: ...A2000 01 issue 02 2016 ABMESSUNGEN Panel mounting in front of the panel Panel mounting behind the panel 3 1 2 DA2000 K Wall mounting Anschlussstutzen HINTEN Anschlussstutzen UNTEN ø 1 2 2 ø120 ø134 41 60 80 a 100 ...

Page 8: ...8 Doc no DA2000 01 issue 02 2016 3 1 3 DA2000 series in IP66 protective housing Wall mounting DA2000 K S Wall mounting DA2000 S Wall mounting DA2000 A S MONTAGE ...

Page 9: ...9 Doc no DA2000 01 issue 02 2016 4 Electrical connection DA2000 A Connection diagram two wire circuit DA2000 A Connection diagram three wire circuit DA2000 K Connection diagram pressure switch MONTAGE ...

Page 10: ...ernal influences and force majeure 7 Disposal Dispose of parts so as not to endanger the human health or environment Follow the laws in the country of use for disposing of electronic components and devices during disposal WARRANTY SUPPORT 5 Maintenance The DA2000 contains no wearing or consumable parts Servicing is not required On request Arthur Grillo GmbH offers an annual calibration with factor...

Page 11: ...closed contact NC normally open contact NO supply COM 0 10V 3 wire circuit supply voltage 15 30Vdc or 24Vac 4 20 mA 2 wire circuit supply voltage 12 30Vdc rectangle plug connector 16 mm or color coded cable approx 50 cm long IP54 DA2000 DA2000 A DA2000 K IP66 DA2000 S DA2000 A S DA2000 K S Manometer Measurment range Display Overload protection Static pressure Pressure connection Housing Ambient te...

Page 12: ...correction 1 2011 06 Electromagnetic compatibility EMC Part 6 2 Generic standards Immunity for industrial environments DIN EN 61000 6 3 2011 09 Electromagnetic compatibility EMC Part 6 3 Generic standards Emission standard for residential commer cial and light industrial environments You can order the Declaration of Conformity at Arthur Grillo GmbH Am Sandbach 7 40878 Ratingen Phone 0 21 02 47 10 ...

Reviews: