Input Signals

AH15D X2HDA / AH17D X2HDA / AH19D X2HDA / AH22D X216A

RESOLUTION

Horizontal freq (KHz)

Vertical freq (Hz)

Scanning type

800x600@60Hz

37.879

60.317

Progressive

800x600@72Hz

48.077

72.188

Progressive

800x600@75Hz

46.875

75.000

Progressive

1024x768@60Hz

48.363

60.005

Progressive

1024x768@70Hz

56.476

70.070

Progressive

1024x768@75Hz

60.023

75.030

Progressive

1280x720@60Hz

44.697

59.915

Progressive

1280x768@60Hz

47.396

59.995

Progressive

1360x768@60Hz

47.720

59.799

Progressive

1280x1024@60Hz

63.981

60.020

Progressive

1680x1050@60Hz

65.160

59.944

Progressive

1600x1200@60Hz

74.479

59.967

Progressive

1920x1080@60Hz

67.500

60.000

Progressive

Summary of Contents for AH15D X2HDA

Page 1: ...AH15D X2HDA AH17D X2HDA AH19D X2HDA AH22D X216A Retractable monitors for furniture integration User manual ...

Page 2: ......

Page 3: ...nts EC REGULATIONS SECURITY 6 SAFETY INSTRUCTIONS 7 APPLICATIONS 8 FEATURES 8 BOX CONTENTS 9 CONNECTIONS 9 CONTROLS 10 OSD MENU 12 INPUT CONNECTORS 15 WARNING 16 AHnet PROTOCOL 17 INPUT SIGNALS 19 PRODUCT WARRANTY 21 ...

Page 4: ......

Page 5: ...the screens are a part of the interior design as well as essential communication tools Please read this installation and operating instructions carefully and keep them in a safe place for future reference We remain at your entire disposal if you have any suggestions that would help us improve our products Henrik Holm General Manager ...

Page 6: ...s un insulated voltages inside some of the components of sufficient magnitude to expose people to risk of electronic shock This symbol draws attention to important use and maintenance instructions in the manual that accompanies the unit This symbol indicates that the equipment conforms to the norms established by the European Community ...

Page 7: ...t be connected to an electrical outlet with grounding connection protection The operating electrical outlet must be in an easily accessed place ENVIRONMENT Install the equipment on an elevated flat surface Install the equipment in a ventilated area Avoid exposing the equipment to Rain or water Excessive heat cold or humidity Areas exposed to direct sunlight Dirty areas Equipment generating strong ...

Page 8: ...specially designed for desk integration at Conference rooms Meeting rooms Board rooms Auditoriums Information desks Training rooms FEATURES TFT Active Matrix display AH15D X2HDA FULL HD 15 6 AH17D X2HDA FULL HD 17 3 AH19D X2HDA FULL HD 18 5 AH22D X216A FULL HD 21 5 Retractable monitor with electrical engine for furniture integration and tilting screen 20 factory adjusted Up Down function operated ...

Page 9: ...ng the power 1 Open the hatch and remove the two foam protection pieces before connecting the monitor 2 Install the unit on a table or desk in vertical position Power connection 1 Plug the power cable from the power supply into an AC socket of 100 240 Vac 50 60Hz 2 Plug the 12Vdc cable into the socket on the unit Power connection 1 Use the DVI I input to connect a DVI D signal or an analog RGB sig...

Page 10: ...itor there is a screen to configure the monitor Press the UP or DOWN buttons to change the function Press the OK button to select the function Change the parameter using the UP or DOWN buttons and press OK again to save the changes AHnet ID Selects the number AHnet ID to RS422 to externally control the monitor Input select Selects the input source signal DVIA DVI1 or DVI2 Brightness Configuration ...

Page 11: ...truct the rising of the display are not on the top of the cover plate To elevate the monitor display press the rear button 1 on the right hand side of the cover plate 2 Retracting the monitor It is recommended that no objects or parts of the body that could obstruct the retracting movement of the display are not on the top of the cover plate To retract the monitor display press the front button 2 ...

Page 12: ...monitor Press the OK button to enable the item When a function is selected press the LEFT and RIGHT buttons in order to change the parameter of the function Press the Menu button to access to the main menu PICTURE Picture Mode Adjusts the mode of the image Dynamic Standard Mild User Contrast Brightness Colour Sharpness Tint Colour Temperature Adjusts the color of the image Cool Medium Warm User Re...

Page 13: ...e Reduction Adjusts the image noise filter Off Low Middle High Default Screen Only for analogue signals Auto Adjust Horizontal Pos Vertical Pos Size Phase Backlight Adjust the backlight of the screen Colour Range 0 255 16 235 ...

Page 14: ... Adjusts the parameters as factory Blending OSD window transparency Low Middle High Off OSD Duration Adjusts the time that the OSD menu window remains on screen Software Update USB Used for firmware upgrade Mirror 0 Image with no flip 1 Vertical flip 2 Horizontal flip 3 Rotate ...

Page 15: ...12V D C Power supply input connector XLR 4 connector 1 2 Ground 3 4 12Vdc GPI Monitor external contact close control SubD9 female 1 GPI1 2 GPI1 3 GPI2 4 GPI2 5 GPI3 6 GPI3 7 N C 8 12Vdc 600mA max 9 Ground Use GPI1 1 12Vdc 2 Ground to open the monitor Use GPI3 6 12Vdc 5 Ground to close the monitor Termination Activate ON the termination ONLY on the last unit of the RS422 bus AHnet RJ45 CAT5 connect...

Page 16: ...accidentally spilled on the surface cut the power supply and dry it with a cloth Don t restore the power supply until it s completely dry Do not insert objects of any kind into the cabinet slots as they may touch dangerous voltage points which can be harmful or fatal or may cause electric shock fire or equipment failure If the monitor or glass is broken do not come in contact with the liquid cryst...

Page 17: ... RX 4 NC 5 NC 6 Data RX 7 NC 8 NC CONNECTION Pins 1 2 The units respond Pins 3 6 The units receive instructions Protocol to control the monitor by addressable RS422 bus You can connect up to 30 monitors on the same RS422 bus You can use a AH Interface Ethernet to control the RS422 bus The units should have a set address and the address must start by 1 Maximum cable length between ends 500m 1640 ft...

Page 18: ...XX 02 01 00 FA XX 02 00 00 SCREEN OFF FB XX 02 00 00 FA XX 03 01 00 DVI A SELECTION FB XX 03 01 00 FA XX 03 00 00 DVI 1 SELECTION FB XX 03 00 00 FA XX 03 03 00 DVI 2 SELECTION FB XX 03 03 00 FA XX 04 01 00 BUTTON LOCK FB XX 04 01 00 FA XX 04 00 00 BUTTON UNLOCK FB XX 04 00 00 FA XX 14 00 00 INQUIRY CONTROL BYTE FB XX 14 CB1 CB2 XX Number of the monitor address Up to 30 monitors for each RS422 BUS ...

Page 19: ... protocol CB1 BITE 7 6 5 4 3 2 1 0 CLOSED 1 1 0 1 OPENED 0 1 0 1 SCREEN ON 1 SCREEN OFF 0 DVI A 0 0 DVI 1 D 1 1 DVI 2 D 1 0 PROTECTION STOP 1 MONITOR OK 0 CB2 BITE 7 6 5 4 3 2 1 0 BUTTON LOCK 1 BUTTON UNLOCK 0 ...

Page 20: ...each RS422 BUS ZZ Level of the function selected 00 99 Dec COMMAND DESCRIPTION RESPONSE FA XX 15 01 ZZ SET BACKLIGHT LEVEL FB XX 15 01 ZZ FA XX 16 01 ZZ SET CONTRAST LEVEL FB XX 16 01 ZZ FA XX 17 01 ZZ SET BRIGHTNESS LEVEL FB XX 17 01 ZZ XX Number of the monitor address Up to 30 monitors for each RS422 BUS ZZ Level of the function selected 00 99 Dec To send an order to all the monitors you must us...

Page 21: ...5 75 000 Progressive 1024x768 60Hz 48 363 60 005 Progressive 1024x768 70Hz 56 476 70 070 Progressive 1024x768 75Hz 60 023 75 030 Progressive 1280x720 60Hz 44 697 59 915 Progressive 1280x768 60Hz 47 396 59 995 Progressive 1360x768 60Hz 47 720 59 799 Progressive 1280x1024 60Hz 63 981 60 020 Progressive 1680x1050 60Hz 65 160 59 944 Progressive 1600x1200 60Hz 74 479 59 967 Progressive 1920x1080 60Hz 6...

Page 22: ...elp to save valuable resources and prevent any potential negative effects on human health and the environment which could otherwise arise from inappropriate waste handling Please contact your local authority for further details of your nearest designated collection point Penalties may be applicable for incorrect disposal of this waste in accordance with national legislation For business users in t...

Page 23: ... faulty electronic and or mechanical components arising from incorrect installation unauthorized modification and inadequate transport or as a result of atmospheric phenomenon B Labour Albiral Display Solutions S L covers labour costs for replacement of any defective parts in accordance to paragraph A during the period of this warranty C Transport costs I In the case that a manufacturing defect oc...

Page 24: ...S00 MU 17180 ES00 MU 17301 ES00 MU 17322 ES00 MU 17376 ES00 MU 1741 ES00 MU 17445 ES00 P 248121 DEEP P 24821 ESEP P 24821 FREP P 24821 GBEP P 24821 ITEP This manual can be modified without previous notice ENG June 2017 Fàtima 25 Sant Hipòlit de Voltregà 08512 Barcelona Spain tel 34 93 850 23 76 23 83 fax 34 93 850 25 50 23 72 web www arthurholm com e mail marketing arthurholm com Our Product Paten...

Reviews: