retracting. When in Conference model, the microphone will always be 
active and both the light ring and the access to the push button on 
the cover plate will be available via GPI and GPO for remote control.

DynamicTalk is available in 3 sizes:  for 400 mm, 500 mm and 600 
microphones. The system can  be adjusted to the exact length of the 
microphone via AHnet and AHlink. The AHlink is an excellent tool to 
diagnose, verify and configure DynamicTalk.

Features

•  Universal lift system for gooseneck XLR 3 pin microphones
•  Stainless steel cover plate with 3 buttons
•  LED lighting ring to indicate microphone status, 360º
•  Serial control and remote diagnosis 
•  Individual addressing 
•  AH-AMMC Auto Mechanical Movement Calibration 
•  PA and Conference working modes

Box Contents

Before the installation of your DynamicTalk, please check the contents 
of the shipping box, it must contain the following items:
•  DynamicTalk
•  Power cord
•  Power supply 100-240Vac, 50-60Hz. Output 12V 
•  User Manual

Important Note: This device can only work with the power supply 
included in the shipping box. This power supply can not be replaced by 
any other rather than the original one.

Caution! Never use this monitor in horizontal position.

APPLICATIONS

Summary of Contents for AHDTL

Page 1: ...User Guide Danish craftmanship Mediterranean soul Technology Serving Desing AHDTL Universal motorised lift system for gooseneck microphones ...

Page 2: ......

Page 3: ...EGULATIONS AND SECURITY 6 SAFETY INSTRUCTIONS 6 APPLICATIONS 8 FEATURES 9 BOX CONTENTS 9 CONTROLS 10 CONNECTIONS 12 PRODUCT HANDLING 14 AHNET PROTOCOL 15 AHLINK 18 INFORMATION ON DISPOSAL 21 WARRANTY TERMS AND CONDITIONS 22 ...

Page 4: ... and help the decision making Our vision is to facilitate communication through innovative and exclusive design technology that integrates seamless in the furniture design Please read this guide carefully If you have any suggestions that might help us to improve our products we would be pleased to receive them Thank you again and we hope that you enjoy the Arthur Holm experience Henrik Holm Genera...

Page 5: ...ts whose designs are based on quality materials and the latest technology Products which endow meeting and conference rooms with silent ergonomic innovative and aesthetic solutions that integrate into the furniture hang from the walls as works of art or are used as interactive points of information The world of Arthur Holm Arthur Holm offers a selection of unique elegant versatile flexible and erg...

Page 6: ...maximum allowed by the cable used Do not place anything on the power cord Do not locate this product where a person may walk or trip over the cord EC REGULATIONS AND SECURITY ATTENTION Do not disassemble or modify the device in any way This symbol warns of the presence of dangerous un insulated voltages inside some of the components of sufficient magnitude to expose people to risk of electronic sh...

Page 7: ... the equipment to Rain or water Excessive heat cold or humidity Area exposed to direct sunlight Dirty areas Equipment generating strong magnetic fields Avoid placing open containers of liquid near the equipment Keep a minimum distance of 30 mm in order to have good ventilation Never place above the device any sources of flames such as lighted candles etc If you are using the device in extreme weat...

Page 8: ...s Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced AV technician for help APPLICATIONS DynamicTalk is an elegant retractable system for gooseneck microphones with exclusive features It not only makes the m...

Page 9: ...microphones Stainless steel cover plate with 3 buttons LED lighting ring to indicate microphone status 360º Serial control and remote diagnosis Individual addressing AH AMMC Auto Mechanical Movement Calibration PA and Conference working modes Box Contents Before the installation of your DynamicTalk please check the contents of the shipping box it must contain the following items DynamicTalk Power ...

Page 10: ...nally control other devices Contact close of the GPO pins 7 8 while pressing this button 3 TALK or GPO The third push button has two different functions PA mode In PA mode this button is used as the MUTE function Press the button once and the LED ring will appear in red indicating that the MUTE function is deactivated and it s ready for the user to talk to the audience Press the button again to ac...

Page 11: ...nt on GPO connector to externally control other devices Contact close of the GPO pins 9 10 while pressing this button 4 Dynamic LED Ring The system has a LED Ring to indicate the status of the microphone RED indicates that the MUTE function is deactivated and GREEN indicates that the MUTE is activated When the equipment is configured to work on Conference mode the LED Ring is externally controlled...

Page 12: ...keys and press OK to save the new address RS422 bus termination Press key to activate the RS422 termination Press key to deactivate the RS422 termination GPI GPO external contact close connector 1 GND 2 Command microphone UP connecting to GND Connecting to GND more than 2 seconds activates the AHlink signal 5 beeps sounds when the AHlin signal is activated 3 Command microphone DOWN connecting to G...

Page 13: ...13 Service Used for firmware upgrade 12V D C Power supply input connector XLR 4 connector 1 2 Ground 3 4 12Vdc CONNECTIONS ...

Page 14: ...orrect product usage of the DynamicTalk microphones To avoid any product malfunctions do not attempt to bend the microphone to the incorrect angle or outside the microphone s working area Please note that ware to the microphone and pop screen surface can occur ...

Page 15: ... NC 5 NC 6 Data RX 7 NC 8 NC Connection PINS 1 2 The units respond PINS 3 6 The units receive instructions Protocol to control the monitor by addressable RS422 bus You can connect up to 30 monitors on the same RS422 bus It is possible to use a AH Interface Ethernet to control the RS422 bus The units should have a set address and the address must start by 1 Maximum cable length between ends 500m 16...

Page 16: ...00 FA XX 01 00 00 GO DOWN FB XX 01 00 00 FA XX 02 01 00 MUTE ON Only on PA mode FB XX 02 01 00 FA XX 02 00 00 MUTE OFF Only on PA mode FB XX 02 00 00 FA XX 04 00 00 BUTTON LOCKED FB XX 04 00 00 FA XX 04 01 00 BUTTON UNLOCKED FB XX 04 01 00 FA XX 14 00 00 INQUIRY CONTROL BYTE FB XX 14 CB1 CB2 XX Number of the DynamicTalk address Up to 30 units for each RS422 BUS CB1 Response in 8 bits of the device...

Page 17: ... POSITION BIT 2 MUTE ON 1 BIT 3 BUTTON LOCKED 1 BIT 4 BIT 5 BIT 6 BIT 7 1 FAILURE IN THE SYSTEM To send an order to all the devices you must use the address F7 Hex Byte1 In this case the units will not respond Use shielded FTP RJ45 cables for RS422 BUS ...

Page 18: ...e AHlink signal if there is no device mobile or tablet connected for more than 2 minutes You can also deactivate the AHlink signal using the APP on mobile or tablet When the AHlink signal is deactivated a long beep sounds indicating that the AHlink is not longer available on the unit To control and set up the unit using AHlink download AHlink from the App Store IOS system or from Google Play Andro...

Page 19: ...t close to GND GPI pin2 during 2 seconds You will hear 5 beeps indicating that the AHlink signal is activated The AHlink name always begins with AH characters and the fourth last MAC AHlink address Select the device to control and set up the unit When selecting the device the first page will upload This page is used to check the device and for basic installation set up ...

Page 20: ...rence mode AHnet ADDRESS Configuration of the AHnet address of the unit TERM Configuration of the RS422 termination Activate the RS422 termination only in the last unit of the RS422 Bus MIC Controls the microphone on PA mode COMMAND Shows the last AHnet RS422 command received MIC_LENGHT Microphone length configuration in steps One step is aprox 1 cm VER Firmware version MODE Dynamic Talk working m...

Page 21: ...ll help save valuable resources and prevent any potential negative effects on human health and the environment which could otherwise arise from inappropriate waste handling Please contact your local authority for further details of your nearest designated collection point Penalties may be applicable for incorrect disposal of this waste in accordance with national legislation For business users in ...

Page 22: ...splay Solutions Although Albiral Display Solutions S L pays for freight and insurance costs Albiral Displays Solutions will not be responsible for any damages caused by the transportation of the goods if the customer does not inform in writing when receiving the goods 3 2 After 90 days of the purchase date the beneficiary of the warranty will pay both freight and insurance costs Albiral Display So...

Page 23: ...ransportation 8 The warranty is not valid if the beneficiary of the warranty does not include a RMA form and a copy of the purchasing invoice Please note that laws vary from country to country and the same provisions of this warranty may not apply to you If you have any doubts concerning the terms of this warranty please contact business albiral com 34 938 502 376 Copyright Dec 2019 All rights res...

Page 24: ...us notice ENG December 2019 Patents MU17180ES00 MU17301ES00 MU17322ES00 MU17413ES00 MU17445ES00 MU17854ES00 MU17868DEPC MU17868RUPC P24821DEEP P24821ESEP P24821GBEP P24821USPC P27178DEEP P27178EPDV01 P27178EPPC P27178ESEP P27178ITEP P27178RUPC P27178USPC P27284DEEP P27284EPPC P27284ESEP P27284GBEP P27284RUPC P27284USPC P27715ESEP P28089DEEP P28089ESEP P28089ITEP P28089USPC P28090EP00 P31160ESES P3...

Reviews: