10
User manual
AHnet Protocol
›
›
Communication›type›:›RS422
›
›
Connection›type›:›RJ45
›
›
Wiring›type›:›CAT-5
›
›
Speed›and›configuration›:
›
–
Baud›Rate›=›38400
›
–
Data›Bits›=›8
›
–
Parity›=›None
›
–
Stop›Bits›=›1
WIRING›DIAGRAM
Pins 1&2
:›the›units››respond
Pins 3&6
:›the›units›receive›instructions
Protocol›to›control›the›monitor›by›addressable›RS422›bus.›Up›to›30›monitors›can›be›connected›to›the›same›RS422›bus.›
It›is›possible›to›use›a›AH›Interface›Ethernet›to›control›the›RS422›bus.›The›units›should›have›set›an›address›and›the›address›
must›start›by›1.›Maximum›cable›length›between›ends›is›500m.
1.› Data›TX+
2.› Data›TX-
3.› Data›RX+
4.› NC
5.› NC
6.› Data›RX-
7.› NC
8.› NC
AHnet Protocol
AHnet›PROTOCOL
Using›5›bytes›communication:
BYTE 0
START›BYTE
BYTE 1
ADDRESS›BYTE
BYTE 2
COMMAND›BYTE
BYTE 3
VALUE›1
BYTE 4
VALUE›2