14
User manual
AHlink
After›selecting›the›device,›the›page›shown›below›appears›on›screen.
›
Serial
:›Serial›number›of›the›unit
›
Ver
:›Firmware›version
›
MOV
:›Control›for›the›open/close›mechanical›functions
›
AHNetRx:
Last›AHnet›command›received
›
Sensor status:
Sensor›status›information
–
S1, S2
:›Not›used
–
S3
:›Open/Close›sensor›switch.›The›sensor›is›Off›while›
pressing›the›Open/Close›button››on›the›cover›plate
–
S4
:›Mechanical›close›sensor.›The›sensor›is›On›when›the›
device›is››››››closed
›
AHnet Address
:››Shows›the›AHNet›address›configured
›
Position
:›Current›position›of›the›mechanics
›
PSW Configuration
:› Use› “4002”› password› to› change› the›
unit›settings.›Be›aware›to›modify›the›unit›parameters