18
AHLINK
SERIAL
Serial number information on the device
OPEN
Opens the unit
CLOSE
Closed the unit
AUTO ADJUST
Auto adjusts the speed and protection
parameters. On selecting this button the
unit will open and close several times and
adjust the speed and protection parameters
automatically
SPEED OPEN FAST
Speed open fast value
SPEED CLOSE FAST
Speed close fast value
PROTECTION OPEN FAST
Protection open fast value
PROTECTION CLOSE FAST
Protection close fast value
Never change the following parameters:
UNIT POINT
Open unit position
THRESHOLD OPEN POINT
Second position where
the speed changes
REGRESSION POINT
Steps that the unit moves in the opposite directon
when the mechanical is blocked
PARKING TIME MSX100
Time for close park unit. Time the unit takes to close
after detecting the closing sensor
SPEED OPEN SLOW
Speed open slow value
SPEED CLOSE SLOW
Speed close slow value
PROTECTION OPEN SLOW
Protection open slow value
PROTECTION CLOSE SLOW
Protection close slow value
THRESHOLD CLOSE POINT
First position where
the speed changes
Summary of Contents for DynamicSpeaker