background image

6

SAFETY INSTRUCTIONS

Plugs

•  Do not dismantle any part of the device power connector.
•   Disconnect the power plug from the AC outlet when the device is not 

going to be used for an indefinite period of time.

Power and extensions cords

•   Use the appropriate power cord with the correct plug type.
•   Do not overload wall outlets or power cords.
•   Make sure the total ampere passed through a extension cord does not  

exceed the maximum allowed by the cable used.

•   Do not place anything on the power cord.
•   Do not locate this product where a person may walk or trip over the 

cord.

EC REGULATIONS AND SECURITY

ATTENTION: Do not disassemble or modify the device in any way. 
This symbol warns of the presence of dangerous un-insulated 
voltages inside some of the components, of sufficient magnitude 
to expose people to risk of electronic shock.

This symbol draws attention to important use and maintenance 
instructions in the manual that accompanies the unit.

This symbol indicates that the equipment conforms to the norms 
established by the European Community.

Summary of Contents for DynamicSpeaker

Page 1: ...DynamicSpeaker AHDSR42W Motorised loud speaker for integration in desks User Guide Danish craftmanship Mediterranean soul Technology Serving Desing ...

Page 2: ......

Page 3: ...TABLE OF CONTENTS EC REGULATIONS SECURITY 6 FEATURES 8 CONNECTIONS 9 CONTROLS AND AUDIO FEATURES 10 MOUNTING INSTRUCTIONS 11 ASSEMBLY INSTRUCTIONS 11 AHnet PROTOCOL 12 AHLINK 15 WARRANTY TERMS 20 ...

Page 4: ...ts whose designs are based on quality materials and the latest technology Products which endow meeting and conference rooms with silent ergonomic innovative and aesthetic solutions that integrate into the furniture hang from the walls as works of art or are used as interactive points of information The world of Arthur Holm Arthur Holm offers a selection of unique elegant versatile flexible and erg...

Page 5: ...kers are a part of the interior design as well as an essential communication tool Please read this installation and operating instructions carefully and keep them in a safe place for future reference We remain at your entire disposal if you have any suggestions that would help us improve our products Henrik Holm General Manager Technology Serving Design ...

Page 6: ...imum allowed by the cable used Do not place anything on the power cord Do not locate this product where a person may walk or trip over the cord EC REGULATIONS AND SECURITY ATTENTION Do not disassemble or modify the device in any way This symbol warns of the presence of dangerous un insulated voltages inside some of the components of sufficient magnitude to expose people to risk of electronic shock...

Page 7: ... the equipment to Rain or water Excessive heat cold or humidity Area exposed to direct sunlight Dirty areas Equipment generating strong magnetic fields Avoid placing open containers of liquid near the equipment Keep a minimum distance of 30mm in order to have good ventilation Never place above the device any sources of flames such as lighted candles etc If you are using the device in extreme weath...

Page 8: ...reproduction Horizontal surfaces High gain before feedback Speech intelligibility enhancement Active speaker Remotely controllable Balanced sound level distribution Limited audio pollution Low ambient acoustic influence Matching surface ready for veneering No building work required Open and close functions controlled by touch button on upper cover plate and external ethernet control by RS422 AHnet...

Page 9: ...is a loop through connector to use as signal RS422 output Up to 30 devices can be connected on the same RS422 bus TERMINATION Activate ON the termination ONLY on the last unit of the RS422 bus ADDRESS AHNet address for the addressable AHNet command protocol Address 00 is reserved for service SERVICE USB to be used only for service CONNECTIONS ...

Page 10: ...ls 1 Touch button to open and close the unit Audio features 4 coaxial loud speaker Class D 2 way bi amplified RMS power 2 x 36 5 W 360º dispersion Balanced analogue audio input Level line 4dB Internal DSP Frequency response 70Hz 20KHz 10dB ...

Page 11: ...is fixed Diffuser Mounting Guide 961DOC001 00 Dynamic Speaker 1 2 Then press the tactile button to turn the Dynamik Speaker to throug open speaker position 3 Put together the diffusor matching the 4 magnets with the 4 top anchor screws It will detect a clik when the diffusor is in the correct position 1 After unpacking the equipment and removing the safety screw for transport Install the equipment...

Page 12: ... NC 5 NC 6 Data RX 7 NC 8 NC Connection PINS 1 2 The units respond PINS 3 6 The units receive instructions Protocol to control the monitor by addressable RS422 bus You can connect up to 30 monitors on the same RS422 bus It is possible to use a AH Interface Ethernet to control the RS422 bus The units should have a set address and the address must start by 1 Maximum cable length between ends 500m 16...

Page 13: ...X 01 00 00 CLOSE FB XX 01 00 00 FA XX 04 01 00 BUTTON LOCK FB XX 04 01 00 FA XX 04 00 00 BUTTON UNLOCK FB XX 04 00 00 FA XX 09 01 00 MUTE FB XX 05 00 00 FA XX 09 01 01 UNMUTE FA XX 09 02 NN AUDIO GAIN NN 00 0dB 46 70db FA XX 14 00 00 INQUIRY CONTROL BYTE FB XX 14 CB1 CB2 XX Number of the DynamicTalk address Up to 30 monitors for each RS422 BUS CB1 Response in 8 bits of the device status CB2 Respon...

Page 14: ...PROTOCOL CB1 BITE 7 6 5 4 3 2 1 0 CLOSED 1 0 OPENED 0 1 PROTECT 1 NO PROTECT 0 BUT_EN 0 BUT_DIS 1 To send an order to all the devices you must use the address F7 Hex Byte1 In this case the units will not respond ...

Page 15: ...e the AHlink function by pressing the open close button on the cover plate during 3 seconds Using a mobile phone download the EZ App Lynx app from the App Store IOS system or Google Play Android system This App is cost free Execute the EZ App Lynx on your mobile phone ...

Page 16: ...16 AHLINK Select the Scan for local devices option and your AH device will appear on screen The name of the device is AH 4 character Bluetooth MAC address ...

Page 17: ...SOR STATUS Sensor status information S1 S2 Not used S3 Open Close sensor switch The sensor is Off while pressing the Open Close button on the cover plate S4 Mechanical close sensor The sensor is On when the device is closed AHnet ADDRESS Shows the AHnet address configured POSITION Current position on the mechanics PSW CONFIGURATION Use 4002 password to change the unit settings Be aware to modify t...

Page 18: ...TECTION CLOSE FAST Protection close fast value Never change the following parameters UNIT POINT Open unit position THRESHOLD OPEN POINT Second position where the speed changes REGRESSION POINT Steps that the unit moves in the opposite directon when the mechanical is blocked PARKING TIME MSX100 Time for close park unit Time the unit takes to close after detecting the closing sensor SPEED OPEN SLOW ...

Page 19: ...ll help save valuable resources and prevent any potential negative effects on human health and the environment which could otherwise arise from inappropriate waste handling Please contact your local authority for further details of your nearest designated collection point Penalties may be applicable for incorrect disposal of this waste in accordance with national legislation For business users in ...

Page 20: ...splay Solutions Although Albiral Display Solutions S L pays for freight and insurance costs Albiral Displays Solutions will not be responsible for any damages caused by the transportation of the goods if the customer does not inform in writing when receiving the goods 3 2 After 90 days of the purchase date the beneficiary of the warranty will pay both freight and insurance costs Albiral Display So...

Page 21: ...ransportation 8 The warranty is not valid if the beneficiary of the warranty does not include a RMA form and a copy of the purchasing invoice Please note that laws vary from country to country and the same provisions of this warranty may not apply to you If you have any doubts concerning the terms of this warranty please contact business albiral com 34 938 502 376 Copyright Dec 2019 All rights res...

Page 22: ...nt Hipòlit de Voltregà 08512 Barcelona Spain tel 34 93 850 23 76 23 83 fax 34 93 850 25 50 23 72 web www arthurholm com e mail marketing arthurholm com This manual can be modified without previous notice ENG December 2019 P27178ITEP P27178RUPC P27178USPC P27284DEEP P27284EPPC P27284ESEP P27284GBEP P27284RUPC P27284USPC P27715ESEP P28089DEEP P28089ESEP P28089ITEP P28089USPC P28090EP00 P31160ESES P3...

Reviews: