background image

WELCOME

Thank you for purchasing an ARTHUR HOLM product.

Please, read this installation and operating instructions carefully and keep 
them in a safe place for future reference.

We remain at your entire disposal if you have any suggestions.

Henrik Holm
General Manager
hholm@albiral.com

Summary of Contents for DynamicTabLift

Page 1: ...User Guide Danish craftmanship Mediterranean soul Technology Serving Design DynamicTabLift ...

Page 2: ...TENTS REGULATIONS AND SECURITY 5 SAFETY INSTRUCTIONS 5 SYSTEM DESCRIPTION 7 INSTALLATION INSTRUCTIONS 8 POWER AND CONTROL 9 CONTROLS 10 AHnet PROTOCOL 11 INFORMATION ON DISPOSAL 14 WARRANTY TERMS AND CONDITIONS 15 ...

Page 3: ...UR HOLM product Please read this installation and operating instructions carefully and keep them in a safe place for future reference We remain at your entire disposal if you have any suggestions Henrik Holm General Manager hholm albiral com ...

Page 4: ... based on quality materials and the latest technology Products which endow meeting and conference rooms with silent ergonomic innovative and aesthetic solutions that integrate into the furniture hang from the walls as works of art or are used as interactive points of information The world of Arthur Holm Arthur Holm offers a selection of unique elegant versatile flexible and ergonomic products that...

Page 5: ...he cable used Do not place anything on the power cord Do not locate this product where a person may walk or trip over the cord REGULATIONS AND SECURITY ATTENTION Do not disassemble or modify the device in any way This symbol warns of the presence of dangerous un insulated voltages inside some of the components of sufficient magnitude to expose people to risk of electronic shock This symbol draws a...

Page 6: ... the equipment to Rain or water Excessive heat cold or humidity Area exposed to direct sunlight Dirty areas Equipment generating strong magnetic fields Avoid placing open containers of liquid near the equipment Keep a minimum distance of 30 mm in order to have good ventilation Never place above the device any sources of flames such as lighted candles etc If you are using the device in extreme weat...

Page 7: ...positions Serial control Remote diagnosis Box Contents Before the installation of your retractable unit please check the contents of the shipping box it must contain the following items Unit Power cord Remote control 1 per 5 units Power supply 100 2 40Vac 50 60Hz Output 12V User guide Power connection CAUTION Never use this device in horizontal position 1 Plug the power cable from the power supply...

Page 8: ...ablet To place the tablet on the support the support must be on vertical position minimum inclination Once the support is in this position pull the clip up and place the tablet against the support To ensure a correct fit press it while holding the clip up ...

Page 9: ...12Vdc 600mA max 9 Ground Use GPI1 1 12Vdc 2 Ground to open the unit Use GPI3 6 12Vdc 5 Ground to close he unit Termination Activate ON the termination Only on the last unit of the RS422 bus AHnet RJ45 CAT6 connector for addressable RS422 control There is a loop through connector to use as signal RS422 output Up to 30 units can be connected on the same RS422 bus Service Used for firmware s upgrade ...

Page 10: ...o control the UP and DOWN movements function 1 Raising the tablet To rise up the unit press the rear button 1 on the right hand side of the cover plate 2 Retracting the tablet To retract the unit press the front button 2 on the right hand side of the cover plate ...

Page 11: ...Data RX 4 NC 5 NC 6 Data RX 7 NC 8 NC Connection PINS 1 2 The units respond PINS 3 6 The units receive instructions Protocol to control the unit by addressable RS422 bus You can connect up to 30 units on the same RS422 bus You can use an AH Interface Ethernet to control the RS422 bus The units should have a set address and the address must start by 1 Maximum cable length between ends 500 m 1640 ft...

Page 12: ...ION RESPONSE FA XX 01 01 00 GO UP FB XX 01 01 00 FA XX 01 00 00 GO DOWN FB XX 01 00 00 FA XX 04 01 00 BUTTON LOCK FB XX 04 01 00 FA XX 04 00 00 BUTTON UNLOCK FB XX 04 00 00 FA XX 14 00 00 INQUIRY CONTROL BYTE FB XX 14 CB1 CB2 XX Number of the unit address Up to 30 units for each RS422 BUS CB1 Response in 8 bites of the unit status CB2 Response in 8 bites of the unit status ...

Page 13: ...2 1 0 CLOSED 1 1 0 1 OPENED 0 1 0 1 PROTECT STOP 1 LIFT OK 0 CB2 BITE 7 6 5 4 3 2 1 0 BUTTON LOCK 1 BUTTON UNLOCK 0 To send an order to all the units you must use the address 249 Dec Byte1 F9 Hex Byte1 In this case the units do not respond ...

Page 14: ... appears on the LCD screen Then press the OK button and you will hear a 5 Beep sound This means that the AHlink is active The wireless AHlink signal automatically deactivates when there is no device connected during more than 2 minutes When the AHlink deactivates you will hear a long Beep sound To control and set up your AH product with AHlink please download it from the App Store IOS system or fr...

Page 15: ... might no longer be active The AHlink name always begins with the characters AH followed by the four last MAC AHlink address You must select the AH device After selecting the AH device the first page will upload on your screen This page is used for the basic installation setup ...

Page 16: ...nitor movements AHLINK OFF Turns off the AHlink signal COMMAND Information of the last AHnet command received from RS422 port SENSORS Indicates sensor status S1 Unit up position S2 Tablet rotation AHnet ADDRESS AH address settings POSITION Tablet position PASSWORD Access to the factory s settings ...

Page 17: ...ll help save valuable resources and prevent any potential negative effects on human health and the environment which could otherwise arise from inappropriate waste handling Please contact your local authority for further details of your nearest designated collection point Penalties may be applicable for incorrect disposal of this waste in accordance with national legislation For business users in ...

Page 18: ...splay Solutions Although Albiral Display Solutions S L pays for freight and insurance costs Albiral Displays Solutions will not be responsible for any damages caused by the transportation of the goods if the customer does not inform in writing when receiving the goods 5 2 After 90 days of the purchase date the beneficiary of the warranty will pay both freight and insurance costs Albiral Display So...

Page 19: ... warranty there are no damages during transportation 8 The warranty is not valid if the beneficiary of the warranty does not include a RMA form and a copy of the purchasing invoice Please note that laws vary from country to country and the same provisions of this warranty may not apply to you If you have any doubts concerning the terms of this warranty please contact business albiral com 34 938 50...

Page 20: ...pòlit de Voltregà 08512 Barcelona Spain tel 34 93 850 23 76 23 83 fax 34 93 850 25 50 23 72 web www arthurholm com e mail marketing arthurholm com This manual can be modified without previous notice ENG December 2020 P27178ITEP P27178RUPC P27178USPC P27284DEEP P27284EPPC P27284ESEP P27284GBEP P27284RUPC P27284USPC P27715ESEP P28089DEEP P28089ESEP P28089ITEP P28089USPC P28090EP00 P31160ESES P31160P...