6
GAS CONNECTION - LIQUID PROPANE (LP), continued.
NOTE: THIS APPLIES TO LP MODELS ONLY. LP MODELS HAVE THE LETTERS “LP” IN THE
MODEL NUMBER.
NEVER CONNECT THE GRILL TO AN UNREGULATED GAS SUPPLY.
Before proceeding, ensure the unit is fitted for LP gas. Connecting to an improper gas type will result in
poor performance and increased risk of damage or injury.
The installation of this appliance must conform with local codes or, in the absence of local codes, to the
national fuel gas code, ANSI Z223.1a-1988. Installation in Canada must be in accordance with the
Standard CAN/ CGA-B149.1 Natural Gas Installation or CAN/CGA-B149.2, Propane Installation Code.
Manifold pressure with LP
Operating: 10.0” W.C.
Non-operating:
11.2” W.C.
L.P. TANK REQUIREMENTS:
Use only a standard 20 Lb. (5 Gal.) propane gas cylinder (18-1/4” H
x Ø12-1/4”). The tank must be installed in the upright position. Do
not use a dented or rusty LP tank as it may be hazardous and
should be checked by your LP supplier. Never use a cylinder with a
damaged valve. The LP gas cylinder must be constructed and
marked in accordance with the specifications for LP gas cylinders
of the U.S. Department of Transportation (DOT). The cylinder must
be provided with a shut off valve terminating in an LP gas supply
cylinder valve outlet specified, as applicable, for connection type
QCC1 in the standard for compressed gas cylinder valve outlet and
inlet connections ANSI/CGA-V-I.
WARNING
ENSURE THAT THE GAS
SUPPLY HOSE DOES
NOT COME IN CONTACT
WITH THE GRILL BODY
REMOVE FROM BBQ
CONNECT LP
SUPPLY
HOSE HERE
PART NO. 220-0412
1/2” NPTF TEE
(BRASS)
PART NO. 220-0405
1/2” NPT X 3/8” ODF
NIPPLE (STEEL)
PART NO. 220-0411
1/2” NPT X 3/8” ODF
ELBOW (BRASS)
GAS LINE TO
BARBECUE
BURNERS
TO SIDE BURNER
GAS FLOW TO
SIDE BURNER
Summary of Contents for Art-SB1