500-003111-000
5-13
a. Establish bipolar, -10 to +10 V analog outputs as follows:
JUMPER FUNCTION STATE
J12-1, 2
BIPOLAR OUT
INSTALLED
J13
20 V OUTPUTS
REMOVED
J39
OUT RTN GND
INSTALLED
b. Connect the positive lead of the DVM to Pin A31 of P2, and the
negative lead to Pin C31 of P2.
c. Establish zero output levels by writing 0800 to the output
Digital-to-Analog Converter (DAC) Registers at board addresses 04
and 06. Place the outputs On-Line by writing 0800 to the CSR.
d. Adjust R36 (ANA CH-0 ZERO ADJ) for a DVM indication of 0.000
±0.002 VDC.
e. Move the positive lead of the DVM to Pin A32 of P2. Adjust R61 (ANA
CH-1 ZERO ADJ) for a DVM indication of 0.000 ±0.002 VDC.
f. Establish negative full-scale output levels by writing 0000 to the
output DAC Registers.
g. Adjust R60 (ANA CH-1 GAIN ADJ) for a DVM indication of -
10.000 ±0.002 VDC.
h. Move the positive lead of the DVM to Pin A31 of P2. Adjust R35 (ANA
CH-0 GAIN ADJ) for a DVM indication of -10.000 ±0.002 VDC.
i. Establish positive full-scale outputs by writing 0FFF HEX to the output
DAC Registers. Verify that the output levels on pins A31 and A32 of
P2 are +9.995 ±0.004 VDC.
j. Calibration is completed. Remove all test connections. Remove
power. Restore all board jumpers to their original locations.
5.6 CONNECTOR
DESCRIPTIONS
Two 96-pin DIN connectors, P1 and P2 (Figure 2.1-1), connect the
VMIVME-3111 board to the VMEbus backplane. P1 contains the address, data and
control lines, and all additional signals necessary to control VMEbus functions
related to the board.
Rear panel connector P2 accepts 32 single-ended analog inputs or 16
differential inputs, and mates with a 64-pin DIN cable connector. Pin configuration
and signal assignments for P2 are shown in Figure 5.6-1 and Table 5.6-1. Sensing
of remote signal returns through P2 is established by removing the J35 jumper. The
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com