Base Address Configuration
2
Base Address Configuration
There are 20 jumper positions to establish the
Base Address
,
Address Mode
, and
Access
Mode
. The
Address Mode
can be configured for standard or short address space. The
Base Address
is determined by the presence (address bit compared to logic zero [0]) or
absence (address bit compared to logic one [1]) of a jumper shunt at each appropriate
address jumper position. For
Short
and
Standard Address Mode
configurations, the
address jumper positions which must be configured are A[15:8] or A[23:8],
respectively. The
Access Mode
can be configured for supervisory, nonprivileged, or for
both supervisory and nonprivileged access.
Jumper functions are illustrated in Figure 2-1 below and Figure 2-2 on page 36.
Figure 2-3 belowshows the location of user configurable jumpers. Omission of a
jumper shorting plug produces a HIGH (logic one [1]) requirement for the associated
control bit. Installation of the jumper shorting plug produces a LOW (logic zero [0])
requirement. The factory configuration for the board is:
Standard Address Mode
,
Supervisory
and
Nonprivileged Access Mode
, and base address set at
0XFB00 0000.
Figure 2-1 Address Locations and Configuration
Pin No.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
A23
A22
A21
A20
A19
A18
A17
A16
A15
A14
A13
A12
A11
A10
A9
A8
E9
Address Locations A[23:8]
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com