16
BLOCK CONNECTIONS DIAGRAM
Technical Data
Nominal voltage
220-240v AC 50/60Hz
Total connected load
max. 15kw (max. 6A)
Switching current each channel 6A at cos phi = 1
Power Vcc1
max. 10w
System of preotection
IP55
Housing dimensions
130x95x60mm
1 2 3 L 5 6 7 N 9 10 11 PE
1 2 3 4
S1
ON
4 N 8 PE 12
D6
D4
26
25
Vcc1
29
28
1
E5
E4
E3
E2
E1
S06
E6
13
E1
mains voltage supply
E2
pump or blower
E3
RGB Light 1
E4
RGB Light 2
E5
TL5 whirlpool
E6
switch whirlpool
1 DP-switch for sellings
28, 29 EGB Light
D6 LED for TLS- control
+12V black
brown
blue
+12V Vcc
common
waler
air
light RGB-1 button
lght RGB
light-slup
motor valve
side-LED
GND
26
25
24
23
22
21
20
19
18
17
16
15
14
13
2 but.
switch whirl.
TLS whirl.
DP-switch NO OFF
S1.1
S1.2
S1.3
S1.4
supply voltage Vcc1
10v / 5v
TLS-sensor RGB light
deactivated / active
* dry out
automatic / manual
interval
ON / OFF
WHIRL POOL CNTROL TYPE 240 9043C - S06