10
Laser stripper
– Never run the laser stripper without the
main guard in position. If the unit is being serviced and
test are being run, always wear Laser safety glasses.
SAFETY INTERLOCKS
All safety guards and interlocks should be tested daily or at the beginning of each shift change. It is
recommended that these checks be documented.
GUARD:
Opening the guard will stop the machine and display the warning “Guard Open”. The same
message will appear if the
Master Start
is pressed with the guard open.
There are two operating switches located around the machine. One is on the side of the infeed station
and one is on the side of the operator station.
Momentarily press the top of the rocker switch to open and again on the bottom to close.
Do not hold the down switch on
. The safety re-open feature will not function.
CR11 closed guard
CR open guard
Guard switch