128
CR MACHINE CONFIGURATION
GENERAL TAB
Cr.11 Cr.22 Selection
If this machine is a Cr.11 then the Cr.11 bullet should be checked. If this machine is a Cr.22 then the
Cr.22 bullet should be checked.
Jaw Clamp Time
The shorter the jaw Clamp time the faster the machine will run. However if the Clamp time is too short
the jaw will not properly clamp the wire before stripping, thus causing strip length variation. If the
UnClamp is too short the jaw will not fully open before feeding or dropping the wire. On the leading side
this may cause a wire jam, on the trailing side this may cause the wire to be thrown back onto the
collector when attempting to drop the wire. The minimum values are shown below.
If the tail jaw has more problems than the lead it could be because a flow control has been installed to
decrease the speed. Kit 2-146042 has a flow control valve and instructions 6-146041 describing how to
install it. The normal time for the Jaw closing is 40mS on the Tail and 30mS for the lead. These values
can be increased to see if it helps the problem.
Master Start Timeout
This setting will Master Stop the machine if it is idle, not cycling, for the entered amount of time.
Lead Overhang Limit
This value is not used in the CR series machine
Consecutive Faults Allowed
This is the number of consecutive CFM sigma faults allowed before stopping production. Gross failures
will always stop the machine immediately.
5M/Sec 8M/sec selection
If your machine has a 5M/Sec wire feed drive check this box.
If your machine has a 8M/Sec wire feed drive check this box.
5M/Sec guard
Notice this
transition