27
-
Production Log
– Gives some basic information about machine usage.
-
Controller messages
– Information about E-stop conditions, starting and stopping.
-
Show SLE Data
– No longer in use.
-
Start Force View
– If an operator accidentally closed the Forceview CFM software, click this to
re-open it.
-
Data Error
– Checks the part for programming errors and displays any problems.
-
Display in Inch
– Forces the screen to display all values in English measurement.
-
Display in English
– Forces the screen to display all text in English.
-
Select font
– To select a different font or size to display all text in.
(see section Text Font Selection / Size)
-
Use default font
– Will display default font instead of the currently selected font.
C. Maintenance
-
Machine settings
– Opens the machine settings window. This is for changing pre-process
types, wire collection drop positions, configuring part qualification, configuring material
validation.
(see sections Part Qualification, Material Validation, and Machine settings
)
-
Connect to Controller
– If the machine controller has been reset you can click this instead of
opening and closing the Unity software.
-
IO status
– Displays Input / Output information and servo data.
(see section Maintenance data)
-
Imaje DIO
– For troubleshooting the communication between the Imaje printer and the machine.
-
Counters
– Shows the total number of machine cycles and hour meters.
D. Configuration
-
Device configuration
– Defines the type and location of process stations on the machine.
Normally only used for setup during the initial installation of the machine.
(see section Device Configuration)
-
Machine Configuration
– Configures values such as the jaw clamp time, bade style, collector
type, crimping unit and CFM type. Normally only used for setup during the initial installation of
the machine.
(see section Machine Configuration)
-
Controller ports
– Defines which computer COM ports the serial cables from the machine
controllers are plugged into. Normally only used for setup during the initial installation of the
machine.
-
Download image
– This will force the Artos software to download the firmware to the controller.
Normally only used to download custom software.
E. TUnit
-
IO [unit-1/2]
– Opens the I/O and servo data screen for press 1 and 2.
(see section T-Unit Maintenance data
-
Config Tunit-1/2
– Defines press parameters such as air blow time, home position, press gear
ratio and auto shut configuration. Normally only used for setup during the initial installation of the
machine.
-
Connect to TUnit-1/2
- If the machine controller has been reset you can click this instead of
opening and closing the Unity software.
-
Download image [unit-1/2]
- This will force the Artos software to download the firmware to the
controller. Normally only used to download custom software.
-
Upload data [unit-1/2]
–N/A
-
ForcePack Data
– N/A
-
IO [unit-3/4]
– N/A
-
Config Tunit-3/4
– N/A
-
Connect to TUnit-3/4
– N/A
-
Download image[unit-3/4]
– N/A
-
Upload data [unit-3/4]
– N/A
-
ForcePack Data
- N/A
-
Import TUnit data
– For importing crimping setting data from a *.xml file.
F.
Tools
-
User Administration
– Password configuration and user restrictions. A user can be configured
that will only allow access to certain portions of the software.
(see section System Login / Password)