55
Open barrel terminal example. The Arrive Process and Depart positions would all be set for the same value.
Closed barrel terminal example. The Arrive is out in front of the terminal, the Process is for inserting into the
terminal and the Depart is for pulling back, to get the terminal off the Mylar film.
(see section Closed barrel
Termination)
Height:
Only active with optional power press height. This will raise the crimping unit up or down.
Depart Acceleration:
The acceleration rate at which the arm departs the process position. This affects the strip
and the pivot.
Depart Velocity:
The velocity at which the arm departs the process position. This affects the strip and the pivot.
Pre-Trip Time:
The time in milliseconds, to start the process prior to the wire arriving at the process position,
nominally 75 MS. If this process is a crimping unit this time is automatically calculated during running, so you do
not need to enter a value.
Post-Trip Time
: The time in milliseconds, that the wire will remain in the process position after the process is
tripped, nominally 125 ms. If this process is a crimping unit this time is automatically calculated during running, so
you do not need to enter a value.
Use these arrows to increase or decrease the selected setting.
Click this icon to set the reading to 0.
Click this icon to learn the position. When you learn a position the servo position is transferred from the
motor to the data entry field that is currently selected. This means you can have the machine in e-stop, move the
arm by hand to your desired position, and open the field you wish to program, then click this icon to set the
position. This is a very useful feature for initial setup of a new process.
Process control settings
To edit the process control settings first click on the process name in the list and then click on the Information tab.
Pivot Values
Arrive, Process and
Depart values