Data Restore
This process is normally reserved for disaster recovery. It will overwrite the data that is currently on the machine.
Manual Method
From the main menu bar click File – Restore.
Select the most recent working backup file, and then select Open.
Automatic Method
Delete the directory C:\program files(x86)\Artos Engineering\CR11 if the (x86) directory does not exist on the
computer then delete C:\program files\Artos Engineering\CR11.
Copy the most recent working backup directory to C:\program files(x86)\Artos Engineering\CR11 if the (x86)
directory does not exist on the computer then copy to C:\program files\Artos Engineering\CR11.
Data Export
The data export and data import functions can be used to transfer parts, jobs, wires and process data between
machines or between a desktop computer and the machine.
There are two types of data exports.
1. Export the current part and job that is on the screen. This export will include the Wire Parameters,
process and pre-process data that is used to make the part. From the main menu bar click File – Export
Select the location to create the file in. The file name will already be filled in with the current part name.
If you need a name different than this, change it now.