- 17 -
8-2-1
Trigger timing chart (ARTCAM-036MI2 series)
t0
Input Pulse Width
Above 1ms
t1
Photo Coupler Delay
1
~
99
μs (Subject to Input Pulse Voltage)
t2
Reset Time
6 * 1H
t3
Exposure Time
Subject to Shutter Speed Settings
t4
Frame Transfer
Subject to ROI Settings and Operation Clock
t5
Effective Trigger for next frame
Approximate 100H after the Vertical Synchronization Signal
transits to a low voltage
*For ARTCAM-036MI2, the image will be acquired when the trigger signal transits from a low voltage to a
high one. If the trigger signal stays at a high level, the trigger time cycle will repeat automatically and image will
be acquired continuously.
Image Transfer (USB)
t0
t1
t5
t3
t4
t2
Vertical Synchronization Signal
Last Line
2
nd
Line
Exposure Time
Reset Time
TRIG Signal
Trigger Input
1
st
Line