2.  Safety 

– CAUTION! 

 

  This  UPS  utilizes  voltages  that  may  be  hazardous.  Do  not  attempt  to 

disassemble the unit. The unit contains no user serviceable parts. Only 
factory service personnel may perform repairs. 

  Connection to any other type of receptacle other than a two-pole, three-

wire grounding receptacle may result in shock hazard as well as violate 
local electrical codes. 

 

In the event of an emergency, turn the power switch to the “off” position 
and  disconnect  the  power  cord  form  the  AC  power  supply  to  properly 
disable the UPS 

  Do not allow liquids or any foreign object to enter the UPS. Do not place 

beverages or any other liquid-containing vessels on or near the unit.

 

  Avoid installing the UPS in locations where there is standing or running 

water, or excessive humidity. 

 

Do not plug the UPS’ power cord into itself.

 

  Do not attach a power strip or surge suppressor to the UPS. 

  Do not attach non-computer-related items, such as medical equipment, 

life-support equipment, microwave ovens, or vacuum cleaners to UPS

 

 

To reduce the risk of overheating the UPS, do not cover the UPS’ 
cooling vents and avoid exposing the unit to direct sunlight or installing 
the unit near heat emitting appliances such as space heaters or 
furnaces. 

  Unplug  the  UPS  prior  to  cleaning  and  do  not  use  liquid  or  spray 

detergent. 

  Do  not  dispose  of  battery  or  batteries  in  a  fire.    The  battery  may 

explode. 

  Do not open or mutilate the battery or batteries.  Released electrolyte is 

harmful to the skin and eyes.  It may be toxic. 

  A  battery  can  present  a  risk  of  electrical  shock  and  high  short  circuit 

current. The following precautions should be observed when working on 
batteries : 

1) Remove watches, rings, or other metal objects. 
2) Use tools with insulated handles. 
3) Wear rubber gloves and boots. 

 Servicing  of  batteries  should  be  performed  or  supervised  by  personnel 

knowledgeable  of  batteries  and  the  required  precautions.    Keep 
unauthorized personnel away from batteries.

 

  When replacing batteries, replace with the same number of the sealed 

lead-acid batteries. 

Summary of Contents for ART 600VA

Page 1: ...ART 600VA LINE INTERACTIVE UPS USER MANUAL ...

Page 2: ...I CONTENTS 1 Introduction 1 2 Safety Caution 2 3 System description 4 4 Specification 5 5 Installation and operation 6 6 Battery 8 7 Trouble Shooting 9 ...

Page 3: ...s function enables the UPS to be started up without AC power supplied Although it s a small UPS it s equipped with Smart RS 232 Communication Port to offer users more benefits The download software helps users monitor UPS inside status The main features of UPS are listed below Microprocessor control guarantees high reliability Equipped with Boost and Buck AVR Built in RS 232 Communication Port Fre...

Page 4: ...ed items such as medical equipment life support equipment microwave ovens or vacuum cleaners to UPS To reduce the risk of overheating the UPS do not cover the UPS cooling vents and avoid exposing the unit to direct sunlight or installing the unit near heat emitting appliances such as space heaters or furnaces Unplug the UPS prior to cleaning and do not use liquid or spray detergent Do not dispose ...

Page 5: ...emals das Gerät Das Gerät darf aus Gründen der elektrischen Sicherheit nur von authorisicrtem Servicepersonal geöffnct Wcrdcn Bei der Installation is darauf zu achten das der Gesamtableitstrom der USV und der and der USV angeschlossenen Verbraucher den Maximalwert von 3 5mA nicht überschreiten VORSICHT Explosionsgetahr bei unsachgemäßen Austausch der Batterie Ersatz nur durch denselben order einem...

Page 6: ... Panel 1 Power Switch 2 LED Indicators AC Mode Green lighting Battery Mode Green flashing Back Panel 1 Output receptacles 2 AC input with AC fuse 3 Modem Phoneline Surge Protection 4 Communication Port 5 Circuit Breaker 1 2 3 4 5 ...

Page 7: ...LOAD 10 MINUTES AT HALF LOAD RECHARGE TIME 8 HOURS TO 90 AFTER COMPLETE DISCHARGE TRANSFER TIME TYPICAL LESS THAN 6MS INDICATOR AC MODE GREEN LIGHTING BACKUP MODE GREEN FLASHING AUDIBLE ALARM BACKUP MODE SOUNDING EVERY 10 SECONDS BATTERY LOW SOUNDING EVERY 1 SECOND OVERLOAD SOUNDING EVERY 0 5 SECONDS FAULT CONTINUOUS SOUNDING PROTECTION FULL PROTECTION DISCHARGE OVERCHARGE AND OVERLOAD PROTECTION ...

Page 8: ...echarged prior to use Plug the unit into an appropriate power supply and allow the UPS to charge fully by leaving it plugged in for at least 8 hours with no load no electrical devices such as computers monitors etc connected 3 Placement Install the UPS unit in any protected environment that provides adequate airflow around the unit and is free from excessive dust corrosive fumes and conductive con...

Page 9: ...ailure 8 Free Download Software Win Power Win Power is a brand new UPS monitoring software which provides user friendly interface to monitor and control your UPS This unique software provides safely auto shutdown for multi computer systems while power failure With this software users can monitor and control any UPS on the same LAN no matter how far from the UPS Installation procedure Go to the web...

Page 10: ...s 2 The following precautions should be observed when working on batteries 1 A battery can present a risk of electrical shock and high short circuit current 2 Do not short the battery terminals 3 Do not charge in a gas tight container 4 Do not dispose of battery or batteries in a fire 5 Flush with water at once if contact is made with electrolyte acid Store The Battery gradually loses its capacity...

Page 11: ...ply is normal Overload of the UPS Verify that the load matches the UPS capability specified in the specs When power failure back up time is shorten 1 Overload of the UPS 1 Remove some non critical load 2 Battery voltage is too low 2 Charge battery 8 hours or more 3 Battery defect due to high temperature operation environment or improper operation to battery 3 Replace with the same type of battery ...

Page 12: ... Elektronik San Müm Tic Ltd Şti Adres İMES Sanayi Sitesi D Kapısı Karşısı Kuru Sk No 26 Y Dudullu İstanbul Tel 90 216 365 82 21 pbx Faks 90 216 420 97 70 Web www artronic com tr E posta artronic artronic com tr ...

Reviews: