Wave Select
The LFO offers several modulation waveforms that can be selected using
the switch. The options are; square, sawtooth, and triangle waves.
Amount
The Amount knob regulates how wide the modulation coming from the LFO is. It
allows you to attenuate the level of the signal to get more subtle effects.
Rate
The rate knob allows you to set the speed of the LFO. It allows for a range of .1Hz –
200Hz. When the LFO is sync’d to MIDI Clock (via the settings accessed in the
MicroBrute editor software) or the Sequencer, the rate control will change between
fixed time divisions of the incoming or Seq clock.
These sync’d rates are:
4 measures, 2 measures, 1 measure, ½ note, ¼ note,
The Rate and the LFO sync can be set within the MicroBrute Editor. In the editor, you
can set whether the LFO is Free-running or Reset on each note.
Free-running
– a free running LFO will have a set rate that does not change.
Reset
– the LFO can reset to a default start point on each Note/Sequencer
Gate. This allows you to have the LFO start at the same point on each note on
message.
Sync
This will allow the LFO to run on it
’
s own clock (or external MIDI clock source) in the
FREE setting or have it tied to the timing of the Sequencer with the SEQ setting.
LFO Settings via the MicroBrute Editor
There are a number of settings for the LFO that determine how it operates. These
settings can be accessed via the MicroBrute Editor Software.