Earthing
wire
should
be
installed
in
such manner to be the last
one
pulled
out in case the safety relief
device
of
the
mains
lead should fail
.
Mains lead behind the oven must be
placed in such manner to avoid
touching the back panel of the oven
because of the heat it develops
during operation
.
The cable of correct size rating please
Electric connection
CONNECTION DIAGRAM
Caution! Voltage of heating elements 220-240V
Caution! In the event of any connection the safety
Wire must be connected to the
E terminal.
Recommended
type of
connection
lead
1
For 220-240V earthed one-phase
connection, bridges connect 1-2-3
terminals and 4-5 terminals, safety
wire to
L
N
E
H05VV-F
3G2.5
L=R, N=null terminal, PE=safety wire terminal
1
2
3
4
.
The connection cable must be secured in a strain-relief clamp. For the connection leads,
the grounding wire must be longer than the other wires.
Caution
!
Remember to connect the safety circuit to the connection box terminal marked with . The
electricity supply for the oven must have a
n
all
-
pole
disconnection
switch which enables
the power to be
cut off in case of emergency. The distance between the working
contacts
of
the
safety
switch must be at least 3 mm.
Before connecting the cooker to the power supply it is important to read the information on
the manual.
follow the below diagram.
10
11
CAO888X
CAO888B
CAO888W
CAO888X/1
oven
Warning!
All electrical work must be carried out by
a suitably qualified and authorized
electrician. No alterations or willful
changes in the electricity supply should be
carried out.
Before attempting the connection,
check whether the voltage indicated
on the rating plate corresponds to
the actual mains voltage.
Mains lead should be minimun 1.5m
long.
INSTALLATION
OPERATION
Grill
Fan
Forced
Convection
Fan
Assisted
Half Fan
Grill
Bottom
Light
MAX
MAX
Grill
Convection
Bottom
Defrost