background image

 
 
 
 
LED Spotlight 20W 
Article: 46925 - LED-Spotlight with 20W LED with 2m H05RN-F 3G1,0 
 
 
 
 
 
 
 
 
 
 
Introduction 
Please read the instruction manual completely and carefully. 
The LED spotlights have been designed to be used in protected outdoor locations. 
If the safety guidelines are not adhered to, life threatening situations and injuries as well as 
technical malfunctions (electrical shock, shortcircuit, fire, etc.) can result. 
The LED spotlights are intended to be used in dry indoor locations as well as for permanent 
use in outdoor locations. 
Technical data 
Nominal voltage: 220-240 V AC 
Nominal frequency: 50-60 Hz 
Protection class: IP 65 
LED class: I 
Light colour: 6400K 
ca. 1500Lumen 
Connection 
DANGER: 
Mounting must be carried out by a professional. The person must be familiar 
with the relevant norms, regulations and dangers. 
1 Disconnect the circuit 
It is imperative to disconnect the chosen circuit. 
Danger: Check absence of voltage. 
2 Open connection box 
Unscrew the two Phillips screws from the connection box. 
3 Insert cable 
Unscrew the screws from the cable gland, mains lead cleat and connection brackets. 
Lead the stripped connection cable through the cable gland into the box. 
4 Wiring the LED spotlight 
Connect brown (i.e. black) cable to bracket L, the blue cable to N and thegreen / yellow onto 
the protective earth bracket. (See 
connection plan in theconnection box) 
L = carrying conductor (phase) 
N = neutral conductor (neutral) 
= protective earth (grounding) 
Screw the screws from the cable gland,mains lead cleat and connection brackets back on. 
5 Close connection box 
Close the connection box with the lid and screw closed. 
Safety Precautions: 
To reduce risk of electric shock, this product should ONLY be opened by an authorized 
technician when service is required. 
Disconnect the product from mains and other equipment if a problem should occur. 

Summary of Contents for 46295

Page 1: ...nnungsfreiheit sicherzustellen 2 Öffnen der Anschlussdose Lösen Sie die 4 Kreuzschlitzschrauben auf der Rückseite des Anschlusskastens 3 Kabeleinführung Lösen Sie die Verschraubung am Kabeleingang des Anschlusskastens Führen Sie das abisolierte Anschlusskabel durch die Kabelverschraubung in das Gehäuse ein 4 Verdrahtung der LED Strahler Schließen Sie das braune Kabel an der Klemme L an das blaue K...

Page 2: ...airement environ 1500lumens Schéma de raccordement électrique L Phase fil brun du détecteur N Neutre il bleu du détecteur GNDF Terre fil vert jaune Borne de terre Instructions de montage Assurez vous de la mise hors tension du câble de connexion Dévissez les vis du boitier et fixez le fond du boitier au mur avec les vis et chevilles adéquates Introduire le câble d alimentation approprié au minimum...

Page 3: ...Disconnect the circuit It is imperative to disconnect the chosen circuit Danger Check absence of voltage 2 Open connection box Unscrew the two Phillips screws from the connection box 3 Insert cable Unscrew the screws from the cable gland mains lead cleat and connection brackets Lead the stripped connection cable through the cable gland into the box 4 Wiring the LED spotlight Connect brown i e blac...

Page 4: ...ge van de led schijnwerper de elektriciteit is uitgeschakeld Houd tijdens het gebruik een redelijke afstand tot de verlichte objecten Zie hiervoor afb 3 Probeer te vermijden dat het licht recht naar beneden of onder een scherpe hoek schijnt afb 4 en wijzig dit in een aanvaardbare stompe kleine hoek Volg de instructies op zoals getoond in afb 2 voor het bevestigen van de schijnwerper op gangbare op...

Reviews: