2.5 

 Installation and assembly 

Units  represented  in  this  manual  are  intended  for  indoor  use  only.  Be  sure  the  location  chosen  has  a 
floor strong enough to support the total weight of the unit and contents. For the most efficient operation, 
be sure to provide good air circulation inside and outside of the unit. 

INSIDE CABINET 

The first cleaning must be made when  you unpack the unit and  before switching it on. Clean it 
with  water  and  a  mild  detergent.  When  it  is  clean  and  dry,  insert  the  accessories  in  the 
appropriate places, for the best use of the user. 

OUTSIDE CABINET 

Be sure the unit has good air circulation around it. Avoid hot corners and locations near stoves 
and ovens. It is recommended the unit be installed no closer than 2” from any wall. The place 
where the refrigerator is placed must be open and clean, avoiding that de fan of the condensing 
unit absorbs materials which are deposited then into the condenser blades and coil, which can 
produce failures. 

The unit should not be installed under ambient temperatures higher than 100 °F.  

If  the  relative  humidity  is  higher  than  60  %,  the  door  frames  may  sweat  water.  This  is  not  a 
malfunctioning of the unit.  

2.6 

 Connections 

 

 

Refer to the amperage data in this manual or on data plate and your local code or the National Electrical 
Code to be sure unit is connected to the proper power source. Verify correct incoming voltage according 
to the Data Plate information. 
The data plate in located inside the unit, near the top front left corner. Under any circumstances should 
the data plate be removed from the unit. 
The  data  plate  is  essential  to  identify  the  particular  features  of  your  unit  and  is  of  great  benefit  to 
installers, operators and maintenance personnel. It is recommended that, in the event the data plate is 
removed, you copy down the essential information in this manual for reference before installation. 

OPERATION 

3.1 General information. 
3.2 Control panel description. 
3.3 Machine settings and programs.

 

 

3.1 

 General information 

Good air flow inside the cabinet is critical. Do not block air flow to the fans. Allow three inches of space 
along the front, back, and sides. 

3.2 

 Control panel description 

 

3.2.1

 

Electronic Control 

After connecting your unit, turn ON rocker switch located next to the controller. The display will 
light up  showing  the  temperature  inside  the  unit.  Also,  the  compressor  and  fan  icons  will  flash 
for a period of three minutes. After this delay the unit will start cooling.  

Verify  you  don't  have  any  alarms  on  the  temperature  controller.  If  after  you  turn  ON  the 
equipment the controller shows the alarm icon or an error code, call for technical service. They 
will help you fix the problem. 

Summary of Contents for ACTC-55

Page 1: ...ions Installation and Operation Manuel talimatları Kurulum ve Çalıştırma Manual de instrucciones Uso y mantenimiento Manuel d instructions Installation et fonctionnement Bedienungshinweise Installation und Betrieb Manual do instruções Instalação e Operação Ręczny Obsługa i konserwacja ES EN D T F P P AS OF NOVEMBER 1 2015 ...

Page 2: ...tions 3 2 4 Manufacturer s identification label description 3 2 5 Installation and assembly 4 2 6 Connections 4 OPERATION 4 3 1 General information 4 3 2 Control panel description 4 3 2 1 Electronic Control 4 3 3 Machine settings and programs 5 MAINTENANCE 6 4 1 General safety rules 6 4 2 Machine cleaning and maintenance routine 6 4 2 1 Cleaning the Condenser Coil 6 4 2 2 Draining the Unit 7 4 3 M...

Page 3: ...ompressor mount on right side Cold plate design underneath the pans to keep products fresher and maintain products at 36 46 F temperature in food pans 1 2 Important safety information DANGER Power must be turned off and disconnected from the power source whenever performing maintenance repair or cleaning the condensing unit If machine still running when power is off disconnect power at the circuit...

Page 4: ...or any damages that may have occurred during transportation Visually inspect the exterior of the package if damaged open and inspect the contents with the carrier Any damage should be noted and reported on the delivering carrier s receipt In the event that the exterior is not damaged yet upon opening there is concealed damage to the equipment notify the carrier immediately Notification should be m...

Page 5: ...ms to UL and NSF 7 standards If you want know more about other restrictions about your equipment see the warranty that is located in the final part of your manual 2 4 Manufacturer s identification label description The data plate is located inside the cabinet near the top front left corner Under no circumstances should the data plate be removed from the unit The data plate is essential to identify...

Page 6: ...his manual or on data plate and your local code or the National Electrical Code to be sure unit is connected to the proper power source Verify correct incoming voltage according to the Data Plate information The data plate in located inside the unit near the top front left corner Under any circumstances should the data plate be removed from the unit The data plate is essential to identify the part...

Page 7: ...f the set point for a new temperature press the button DOWN arrow see the picture below Press this button to reach the desired value Release the button and then press the SET button to keep and save the new value Note The minimum value you can set in the controller is For refrigerators 1 C 30 F Manual Defrost To select manual defrost hold the button DOWN arrow for 5 seconds The snow flake icon wil...

Page 8: ... tomatoes and other vegetables 4 2 1 Cleaning the Condenser Coil Disconnect machine Remove front bottom panel and carefully slide out the condensing unit The condenser coil requires regular cleaning recommended every 30 60 days depending of the accumulation of dust and grease If the buildup on the coil consists of only light dust and debris the condenser coil can be cleaned with a simple brush Hea...

Page 9: ...EMBER TO TAKE CARE OF THE ENVIRONMENT TROUBLESHOOTING CHART 5 1 Troubleshooting guide chart 5 1 Troubleshooting Follow the next steps before requesting warranty service Failure to do so may result in service charges for you and may void your warranty 1 Refrigerator doesn t work a Check that the machine is still connected b Check that the ON OFF button is in the ON position 2 Refrigerator doesn t r...

Page 10: ...ed warranty only applies to sealed parts of the compressor and does not apply to any other part or component including but not limited to cabinet temperature control refrigerant motor starting equipment fan assembly or any other electrical or mechanical component Exclusions from and Conditions to Warranty Coverage This Warranty does not cover parts or accessories which a carry the warranty of a su...

Page 11: ...yment of or crediting the user with an amount equal to the purchase price of such goods Prices Specifications Asber reserves the right to change the prices and specifications of the equipment and or material without notice Prices are FOB Asber warehouses All orders are subject to acceptance by Asber Commercial Inc Terms All orders are subject to credit approval All Invoices not paid within the spe...

Reviews: