 Machine settings and programs 

Changing the Set Point of the temperature on the controller 

The unit comes with a factory default set point ( 32°F Refrigerators). These set values will make the unit 
perform at its maximum capacity. Therefore, it is not recommended to change the set point. If set point 
needs to be changed, follow the next steps.  

1.  Push  the  SET  button  for  one  second.  You  should  see  a  flashing  number.  Release  the 

button. 

 

2.  Press the up and down arrows to increase or decrease the set temperature. Then press the 

set button to save the new set point. 

Note: 

The maximum value you can set in the controller is: For refrigerators: 5°C (40°F) 

3.  If  you  wish  decrease  the  value  of  the  set  point  for  a  new  temperature,  press  the  button 

DOWN arrow (see the picture below). Press this button to reach the desired value. Release 
the button and then press the SET button to keep, and save, the new value. 

Note: 

The minimum value you can set in the controller is: For refrigerators: -1°C (30°F) 

Manual Defrost 

To select manual defrost, hold the button DOWN arrow for 5 seconds. The snow flake icon will appear 
on the display. When this icon is solid it indicates that the equipment is in Defrost mode. 

 

To  exit  manual  defrost,  hold  the  DOWN  button  arrow  for  5  seconds.  The  snow  flake  icon  will  turn  off. 
Wait 2 minutes for the compressor to start 

 

 

FIGURE 1 

 

                                           

 

Compressor Icon 

Evaporator Fan Icon 

 

Temperature inside the cabinet 

 

To increase Set Point of Temperature 
To turn the unit ON/OFF without unplugging the 
equipment 

To Change the set point 
To access programming mode 

To decrease Set Point of Temperature 
To set a manual defrost 

Summary of Contents for ACTC-55

Page 1: ...ions Installation and Operation Manuel talimatları Kurulum ve Çalıştırma Manual de instrucciones Uso y mantenimiento Manuel d instructions Installation et fonctionnement Bedienungshinweise Installation und Betrieb Manual do instruções Instalação e Operação Ręczny Obsługa i konserwacja ES EN D T F P P AS OF NOVEMBER 1 2015 ...

Page 2: ...tions 3 2 4 Manufacturer s identification label description 3 2 5 Installation and assembly 4 2 6 Connections 4 OPERATION 4 3 1 General information 4 3 2 Control panel description 4 3 2 1 Electronic Control 4 3 3 Machine settings and programs 5 MAINTENANCE 6 4 1 General safety rules 6 4 2 Machine cleaning and maintenance routine 6 4 2 1 Cleaning the Condenser Coil 6 4 2 2 Draining the Unit 7 4 3 M...

Page 3: ...ompressor mount on right side Cold plate design underneath the pans to keep products fresher and maintain products at 36 46 F temperature in food pans 1 2 Important safety information DANGER Power must be turned off and disconnected from the power source whenever performing maintenance repair or cleaning the condensing unit If machine still running when power is off disconnect power at the circuit...

Page 4: ...or any damages that may have occurred during transportation Visually inspect the exterior of the package if damaged open and inspect the contents with the carrier Any damage should be noted and reported on the delivering carrier s receipt In the event that the exterior is not damaged yet upon opening there is concealed damage to the equipment notify the carrier immediately Notification should be m...

Page 5: ...ms to UL and NSF 7 standards If you want know more about other restrictions about your equipment see the warranty that is located in the final part of your manual 2 4 Manufacturer s identification label description The data plate is located inside the cabinet near the top front left corner Under no circumstances should the data plate be removed from the unit The data plate is essential to identify...

Page 6: ...his manual or on data plate and your local code or the National Electrical Code to be sure unit is connected to the proper power source Verify correct incoming voltage according to the Data Plate information The data plate in located inside the unit near the top front left corner Under any circumstances should the data plate be removed from the unit The data plate is essential to identify the part...

Page 7: ...f the set point for a new temperature press the button DOWN arrow see the picture below Press this button to reach the desired value Release the button and then press the SET button to keep and save the new value Note The minimum value you can set in the controller is For refrigerators 1 C 30 F Manual Defrost To select manual defrost hold the button DOWN arrow for 5 seconds The snow flake icon wil...

Page 8: ... tomatoes and other vegetables 4 2 1 Cleaning the Condenser Coil Disconnect machine Remove front bottom panel and carefully slide out the condensing unit The condenser coil requires regular cleaning recommended every 30 60 days depending of the accumulation of dust and grease If the buildup on the coil consists of only light dust and debris the condenser coil can be cleaned with a simple brush Hea...

Page 9: ...EMBER TO TAKE CARE OF THE ENVIRONMENT TROUBLESHOOTING CHART 5 1 Troubleshooting guide chart 5 1 Troubleshooting Follow the next steps before requesting warranty service Failure to do so may result in service charges for you and may void your warranty 1 Refrigerator doesn t work a Check that the machine is still connected b Check that the ON OFF button is in the ON position 2 Refrigerator doesn t r...

Page 10: ...ed warranty only applies to sealed parts of the compressor and does not apply to any other part or component including but not limited to cabinet temperature control refrigerant motor starting equipment fan assembly or any other electrical or mechanical component Exclusions from and Conditions to Warranty Coverage This Warranty does not cover parts or accessories which a carry the warranty of a su...

Page 11: ...yment of or crediting the user with an amount equal to the purchase price of such goods Prices Specifications Asber reserves the right to change the prices and specifications of the equipment and or material without notice Prices are FOB Asber warehouses All orders are subject to acceptance by Asber Commercial Inc Terms All orders are subject to credit approval All Invoices not paid within the spe...

Reviews: