background image

 

 

11   

asberprofessional.com

 

 

 

     

 

 

 

 

 

 

 

 

      

asberprofessional.com

 

WARRANTY 

5.1 

 Limited Warranty 

ASBER warrants its new product(s) to be free from defects in material and workmanship for a period of one (1) year from the 
original date of installation not to exceed 15 months from date of shipment from our factory. Equipment sold and installed for 
residential use, or outside the continental US is excluded from this warranty. 

This warranty is 

limited to product(s) sold to the original commercial user. The liability of ASBER is limited to, at ASBER’s 

option, the repair or replacement of any part (ground shipping only) found by ASBER to be warranted herein. ASBER shall 
bear the normal labor charges for repair of replacement to the extent that such repair or replacement is performed within (2) 
two hours or up to 100 miles total of the office of an authorized service agency, within the continental US and during regular 
(straight time) hours. Travel outside of the (2) two hours or 100 miles, and any work performed at overtime or weekend rates 
would  be  the  responsibility  of  the  owner/user.  Defective  parts  must  be  returned  to  ASBER,  freight  pre-paid,  for  Warranty 
inspection. 

ASBER assumes no responsibility for any product not installed properly in accordance with the instructions supplied with the 
equipment by an authorized representative. Any equipment which has been modified by unauthorized personnel or changed 
from  its  original  design  is  not  covered  under  this  warranty.  Furthermore,  ASBER  assumes  no  obligation  for  any  product 
which  has  been  subject  to  misuse,  abuse  or  hard  chemicals.  Normal  maintenance  as  outlined  in  the  instructions  is  the 
responsibility of the owner-user and is not a part of this warranty. Normal parts wear and maintenance is also not covered by 
this  warranty.  This  warranty  is  in  lieu  of  any  other  agreement,  expressed  or  implied,  and  constitutes  the  only  warranty  of 
ASBER with respect to the product. 

This states the exclusive remedy against ASBER relating to the product(s) whether in contract or in tort or under any other 
legal, theory, and whether arising out of warranties, representations, instruction, installation or defects’ from any cause.  

ASBER shall not be liable whether in contract or in tort or under any other legal theory for loss of revenue or profit, or for any 
substitute use or performance or for incidental, indirect, special or consequential damages, or for any other loss or cost of 
similar type.  

Proper  installation,  initial  check  out,  air  shutter  adjustments,  or  normal  maintenance  such  as  lubrication,  adjustment  or 
calibration  of  controls  is  the  responsibility  of  the  dealer,  owner-user  or  installing  contractor  and  is  not  covered  by  this 
warranty. 
 

Parts warranty cover 

– ASBER warrants all new machine parts produced authorized by ASBER to be free from defects in 

material  and  workmanship  for  a  period  of  90  days  from  the Warranty  Commencement  Date.  If  any  defect  in  material  and 
workmanship  is  found  to  exist  within  the  warranty  period  ASBER  will  replace  the  defective  part  without  charge.  Defective 
parts become the property of ASBER. 

Warranty Exclusions

 

 
 Negligence or Acts of God. 
 

 

Thermostat calibrations after (30) thirty days from equipment installation due. 

 

Air and Gas adjustments. 

 

Adjustments to burner flames and cleaning of pilot burners. 

 

Failures caused by erratic voltages or gas supplies. 

 

Unauthorized repair by anyone other than an ASBER Authorized Service Center. 

 

Damage in shipment. 

 

Alteration, misuse or improper installation. 

 

If serial number has been removed or altered. 

 

Thermostats and safety valves with broken capillary tubes. 

 

Ordinary wear and tear. 

 

 

Summary of Contents for AECRB-12

Page 1: ...EHP 4 24 AEHP 6 36 AEM G24 B2 36 H AEM G12 B4 36 DOCUMENT CODE Manual instructions Installation and Operation Manuel talimatları Kurulum ve Çalıştırma Manual de instrucciones Uso y mantenimiento Manuel d instructions Installation et fonctionnement Bedienungshinweise Installation und Betrieb Manual do instruções Instalação e Operação Ręczny Obsługa i konserwacja ES EN DE TK FR PT PL ...

Page 2: ...TION OF LEGS 3 2 4 Gas Connections 4 2 4 1 MANUAL SHUT OFF VALVE 4 2 4 2 PRESSURE REGULATOR 4 2 4 3 THIS APPLIANCE IS EQUIPPED FOR NATURAL GAS 4 2 4 4 PRESSURE REGULATOR CONVERSION 5 2 5 Location 5 2 6 CLEARANCES 6 2 7 AIR SUPPLY VENTILATION 6 OPERATION 7 3 1 General information 7 3 2 INITIAL PILOT LIGHTING 7 3 3 LIGHTING SHUTDOWN 7 3 3 1 TOP BURNERS 8 3 3 2 BROILER GRIDDLE 8 3 3 3 BEFORE 1st USE ...

Page 3: ...ead the installation operating and maintenance instructions thoroughly before installing or servicing this equipment FOR YOUR SAFETY Do not store or use gasoline or other flammable vapors or liquids in the vicinity of this or any other appliance 1 3 SPECIFICATION CHART MODEL BTU S LP AT 10 W C ORIFICE SIZE LP BTU S NG AT 5 W C ORIFICE SIZE NG BURNERS ALTITUDE BURNER RANGE SRHP 2 12 46 000 54 60 00...

Page 4: ...ealed damage to the equipment notify the carrier immediately Notification should be made verbally as well as in written form Request an inspection by the shipping company of the damaged equipment Retain all crating material until inspection has been made Finally contact the dealer through which you purchased the unit 2 2 Manufacturer s identification label description Information on this plate inc...

Page 5: ...on making delivery File claim for damages immediately Regardless of extent of damages Concealed loss or damage If damage is noticed after unpacking notify Transportation Company immediately and file Concealed Damage claim with them This should be done within 15 days from date of delivery made to you Retain container for inspection 2 3 1 UNCRATING Cut and remove the outer packaging Cut the 4 clamps...

Page 6: ...coming service line for safe and efficient operation the gas pressure regulator supplied by ASBER must be installed at the gas inlet of each piece of equipment The regulators supplied along with ASBER appliances will have 3 4 inlet outlet openings and are adjusted at the factory for 5 WC natural gas or 10 WC propane gas depending on customer s ordering instructions Prior to connecting the regulato...

Page 7: ...local installation codes Before Installation please read instructions completely and carefully Do not remove permanently affixed labels warnings or plates from the product Please observe all local and national codes and ordinances Installation must conform with local codes or in the absence of local codes the National Fuel Gas Code ANSI Z223 1 latest edition The appliance must be isolated from gas...

Page 8: ...earance must be maintained around the appliance for easy servicing Provision should be made for any commercial heavy duty cooking appliance exhaust combustion waste products to the outside of the building Usual practice is to place the appliance under an exhaust hood which should be constructed in accordance to the local codes Strong exhaust fans in this hood or in the overall air conditioning sys...

Page 9: ...tions Adjustments are the responsibility of the customer and or dealer and are not covered under warranty 3 3 LIGHTING SHUTDOWN Tum all valves or thermostats to the OFF position Wait 5 minutes Turn main gas supply ON and light pilot valves s Adjust pilot valve s screw counter clockwise more flame screw clockwise less flame Adjust pilot flame inch high Turn ON gas valve s to light main burner For c...

Page 10: ...he top Adjustment of the pilot flame can be made with a screwdriver to the pilot valve accessible through the valve cover 3 3 3 BEFORE 1st USE GRIDDLE Clean the griddle surface thoroughly with hot soapy water to remove factory applied protective oil coating Rinse with a mixture of cup vinegar to one quart water Spread unsalted solid shortening or liquid frying compound evenly over the entire gridd...

Page 11: ...f food residue and carefully scrape spillovers from the drip tray below the cooking surface 2 Wash all exterior and interior surfaces with hot soapy water solution Do not use any abrasives on any portion of the stainless or painted surfaces 3 Cast iron grates should be scraped frequently with a wire brush and periodically soaked in hot water solution to remove grease particles 4 Never expose the g...

Page 12: ...OT FLAME NOT ADJUSTED ADJUST PILOT FLAME DRAFT CURRENTS NEAR EQUIPMENT FIX DRAFT NOT ENOUGH VENTILATION CONTACT HVAC CONTRACTOR DEBRIS OR GREASE CLOGGING PILOT BURNER CLEAN DEBRIS AND GREASE FROM PILOT BURNER EXCESSIVE FLARE UP OVERLOAD OF OIL AND LEFTOVERS CLEAN AND PREPARE PAN NOT HEATING PROPERLY ORIFICES DIRTY CLOGGED CLEAN ORIFICE MAKE SURE THERE IS NO RESTRICTION IN THE ORIFICE BURNER LOW GA...

Page 13: ...nty Normal parts wear and maintenance is also not covered by this warranty This warranty is in lieu of any other agreement expressed or implied and constitutes the only warranty of ASBER with respect to the product This states the exclusive remedy against ASBER relating to the product s whether in contract or in tort or under any other legal theory and whether arising out of warranties representat...

Page 14: ...BER Circuito Exportación N 201 Parque Industrial Tres Naciones San Luís Potosí S L P México 13105 NW 47th Ave Miami Fl 33054 www asberprofessional com MULTI SOLUTION MANUFACTURER OF FOODSERVICE EQUIPMENT ...

Reviews: