Page 10
Version 2.00
Assembly Instruction PLG7
Once the angle has been correctly adjusted, the
installation of the travel rails can be continued.
! A T T E N T I O N !
•
Ensure that the mounting brackets are all
positioned vertically.
•
The clearance between the middle of the (lower)
rack and the edge of the steps shall under no
circumstances be lass then the dimension H
provided in the installation drawing.
Failure to observe this will result in collision
between the lift and the stairs!
6.3
Securing the travel rail mounting brackets
Fix the travel rail on each bracket three times to the wall / stanchion.
Use countersunk screws at the upper hole!
The middle and lower screws between the handrail and rack are
not
allowed to protrude
more than 20mm from the bracket!