Assembly Instruction PLG7
Version 2.00
Page 17
13.
Test report after finished installation
OK
Fail
Function control using the remote control (handheld or wall mounted)
Travel up / down
O
O
Platform open / close
O
O
Function test of the key switch (only for wall mounted remote controls)
O
O
Function control using the onboard control
Travel up / down
O
O
Function control for safety equipment
Limit switch, top
O
O
Limit switch, bottom
O
O
Pressure sensitive contact panel (platform underside)
O
O
Emergency stop button
O
O
Switch function test of the access ramps open (travel up / down)
O
O
Switch function test of the access ramps closed (travel up / down)
O
O
Volume test for acoustic alarm
O
O
Shutdown when safety bars are opened while the lift is in motion
O
O
Emergency travel release button (safety bars half open)
O
O
Emergency folding button
O
O
Shutdown when current overload at platform motor
O
O
Function control for mechanical parts and software
Access ramps open and close completely
O
O
Safety bars open and close completely
O
O
Platform open and close completely
O
O
Check battery charger function
O
O
__________________________________
Date, Name
____________________________________
Signature