15.
Service notes
In the interest of health and safety, do not forget to turn off the platform lift via the main switch
(refer to
“
Service Access Hatch
”
) and disconnect it from the electrical supply before
carrying out any form of servicing, repair or maintenance work.
15.1
General maintenance
The following maintenance work can be carried out by the customer / operator or by designated personnel:
•
To remove excessive soiling or dirt from the
toothed travel rails
(black marks of compressed dust), the
rails can be cleaned using a
light lubricating, stainless-steel cleaning spray
.
After cleaning the
upper travel rail
with any form of degreasing agent, the rail should be treated with
stainless steel cleaning spray to ensure a smooth ride.
•
In the course of time the hinges of the access ramps and the platform itself may begin to emit
squeaking noises during operations as a result of friction and wear. This can be eliminated by applying
commercially available lubricant to the affected parts.
•
We recommend removing any excessive soiling or dirt from the platform and ramps with the aid of a
damp cloth or mop and drying thoroughly afterwards before resuming operation.
WARNING!
There is
an increased risk of being cut
by sharp edges when working on the drive rail!
We
recommend that personnel wear safety gloves
while carrying out maintenance work.
15.2
Check emergency features
In addition, all emergency and safety features should be regularly checked for functionality as follows:
Emergency feature
Check timetable
Function
•
Emergency STOP button
press once a month
Lift unit stops
•
Emergency CALL button
press once a month
Audible signal can be heard
•
Pressure sensitive contact
tray (platform underside)
press once every 6 months
Travel DOWN stops
•
Sensors on access ramps
press once every 6 months
Travel UP/DOWN stops
•
Contact sensor strip
press once every 6 months
Lift unit stops
IMPORTANT!
Failure to observe this routine check procedure will result in the guarantee becoming invalid!
15.3
Battery maintenence
The lifespan of the batteries averages 3-5 years.
To ensure the operational reliability of your platform lift, we recommend that the batteries are replaced every
3 years. This should be undertaken by a qualified service technician.
The lift should be operated at least once every 2 weeks.
Use the rain cover included for exterior installations while the lift is not in use in order to protect
it from rain.