Maintenance & Repair Manual
SECTION 3
VIRTUOSO 5460P
6
110057 REV K
SECTION 3: Mechanical Disassembly and Repair
3.1 Important Preliminary Information
The repairs in this section are to be performed by a skilled technician who has
experience working on electro-mechanical systems. Furthermore, the technician should
be well-versed in standard industrial safety practices and procedures. In the United
States of America, electrical safety procedures are established in OSHA's
Lockout/Tagout – Hazardous Energy Sources Standard
(29 CFR 1920.147).
Familiarity with the setup and operation of the lift is required to effectively perform the
repairs listed in this section. This information can be found in the
Operating Manual
provided with the lift.
3.2 Electrically Isolating the Lift
This section describes the procedures for electrically isolating the lift, which is
necessary in order to safely perform some of the repairs covered in this manual.
To electrically isolate the lift, perform the following steps in the order listed:
1. Remove the electrical plug from the wall outlet.
2. Attach a DANGER tag to the end of the electrical plug and lock out the plug
according to the procedures established in OSHA's
Lockout/Tagout – Hazardous
Energy Sources Standard
(29 CFR 1920.147).
3. Coil the electrical cord and place it inside the lift car. This will prevent the cord from
inadvertently being plugged in while repairs are underway.
4. Turn the lift off. The ON/OFF switch is located on the control panel located inside
the left-hand machinery cabinet.
To restore power to the lift, perform the following steps in the order listed:
1. Remove the lock from the electrical plug.