Maintenance & Repair Manual
SECTION 4
VIRTUOSO 5460P
40
110057 REV K
Component Relay
Module
Contacts
Circuit is closed when:
Circuit is open when:
Transport Switch
and Override
Keyswitch
I6-L+
Height adjustment knob is
in transport location and
override keyswitch is
turned "on"
Height adjustment knob is
not in transport location
and override keyswitch is
turned "off"
2" Switch
I5-L+
Lift car is less than 2" off
the ground
Lift car is more than 2" off
the ground
Locking Rod Switch
I4-L+
Upper locking rod is
engaged (lift car is more
than 2" off the ground)
Upper locking rod is
disengaged (lift car is less
than 2" off the ground or
lower landing gate is
open)
Upper Landing Gate
Switch
I3-L+
Upper landing gate is
closed
Upper landing gate is
open
Lower Landing Gate
Switch
I2-L+
Lower landing gate is
closed
Lower landing gate is
open
Upper Stop Switch
I1-L+
Switch is not engaged by
upper stop mechanism
(lift car is not at the upper
landing)
Switch is engaged by
upper stop mechanism
(lift car is at the upper
landing)