IM14194-2
IM14194-DE/GB/FR - 2011/R03 A
vailability
, design and specifications are subject to change without notice
. All r
ights reser
ved.
1. INTRoDUCTIoN
Solenoid valve piloting applications require a high inrush current
to activate the valve. Once activated, only the holding current is
necessary to keep the valve in position. The power-save connector
automatically switches to holding voltage after approx 140 msec
(size 2) or 70 msec (size 30). The holding voltage corresponds to
50% of the inrush voltage. The holding power is thereby reduced to
a quarter of the inrush power. This reduction is particularly efficient
due to PWM operation (pulse width modulation). A green function
LED lights up to indicate valve actuation.
2. ELECTRICAL CoNNECTIoN
+
-
LED
j
LED green
(solenoid valve
actuation)
LED red
(overcurrent
or overtem-
perature
Size 22
Size 30
Screw terminals: up to 1mm² cable
+ = Pilot v
(12V/24V)
– = Pilot voltage –
(GND)
j
=
Earth terminal
(straight through)
+ = Pilot voltage +
(10-30V)
- = Pilot voltage -
(GND)
j
= Earth terminal
1
2
3
3
2
1
Größe 22
Größe 30
1
=
Valve voltage
+
2
=
Valve voltage
-
3
= Earth terminal
1
=
Valve voltage
+
2
=
Valve voltage
-
3
= Earth terminal
d
The valve connector’s earth terminal must be connected
to the system’s ground (PE) in order to provide ESD protec-
tion!
3. LED INDICAToRS
LED green = Solenoid valve actuated (size 22 + size 30)
LED red = Overcurrent or overtemperature (size 30)
4. TECHNICAL CHARACTERISTICS
General
Electrical enclosure protection
IP65
Cable connection
Ø 6-8mm
Electrical characteristics
Size 22
Size 30
Input voltage
12/24 VDC ± 10%
10 to 30 VDC
Output voltage
12 VDC ± 10%
6 to 30 VDC
Power rating
max. 12 W
max. 30 W
Voltage reduction
50% after approx. 140 ms 50% after approx. 70 ms
PWM frequency
7 KHz
50 KHz
operating characteristics
Ambient temperature
-10...+50 °C
Storage temperature
-40...+80 °C
5. DIMENSIoNS
Size 22
Size 30
Notice
The information in these instructions is subject to change without
notice. In no event shall ASCO Numatics be liable for technical or
editorial errors or omissions. Neither is any liability assumed for ac-
cidental or consequential damages arising out of or in connection
with the supply or use of the information contained herein.
Manufacturer’s Declaration according to EU Machinery Directive
We herewith declare that the version of the product described in
this installation manual is intended to be incorporated into or as-
sembled with other machinery and that it must not be put into serv-
ice until the machinery into which it is to be incorporated has been
declared in conformity with the provisions of the EU Directive.
Handling, assembly and putting into service and all adjustments
and fine-tuning must be done by qualified, authorised personnel
only.
This product complies with the EU Directive on electromagnetic
compatibility (as amended). It is CE approved. A declaration of
conformity is available on request. A declaration of conformity with-
in the meaning of the EU Directive is available on request. Please
provide the order number and serial number of the product con-
cerned.
INSTALLATION INSTRUCTIONS
Power-save connectors, industry standard form B (11 mm), ISO 4400 / EN 175301-803, form A,
catalogue nos. 88100934 / 88100944 (size 22), 88100945 (size 30)
GB