1. INTRoDUCTIoN
Solenoid valve piloting applications require a high inrush current 

to  activate  the  valve.  Once  activated,  only  the  holding  current  is 

necessary to keep the valve in position. The power-save connector 

automatically  switches  to  holding  voltage  after  approx  140  msec 

(size 2) or 70 msec (size 30). The holding voltage corresponds to 

50% of the inrush voltage. The holding power is thereby reduced to 

a quarter of the inrush power. This reduction is particularly efficient 

due to PWM operation (pulse width modulation). A green function 

LED lights up to indicate valve actuation.

2. ELECTRICAL CoNNECTIoN

+

-

LED

j

LED green 

(solenoid valve 

actuation)
LED red 

(overcurrent 

or overtem-

perature

Size 22

Size 30

Screw terminals: up to 1mm² cable

 +  =   Pilot v 

(12V/24V)

 –  =   Pilot voltage – 

(GND)

j

  =   

Earth terminal

(straight through)

  +  =  Pilot voltage  + 

(10-30V)

  -  =  Pilot voltage  - 

(GND)

j

  =  Earth terminal

1

2

3

3

2

1

Größe 22

Größe 30

1

  = 

Valve voltage

 +

2

  = 

Valve voltage

 -

3

  = Earth terminal

1

  = 

Valve voltage

 +

2

  = 

Valve voltage

 -

3

  = Earth terminal

d

 

The valve connector’s earth terminal must be connected 

to the system’s ground (PE) in order to provide ESD protec-

tion!

3. LED INDICAToRS

LED green = Solenoid valve actuated (size 22 + size 30)

LED red = Overcurrent or overtemperature (size 30)

4. TECHNICAL CHARACTERISTICS

General
Electrical enclosure protection 

IP65

Cable connection 

Ø 6-8mm

Electrical characteristics
   

Size 22 

Size 30

Input voltage 

12/24 VDC ± 10% 

10 to 30 VDC

Output voltage 

12 VDC ± 10% 

6 to 30 VDC 

Power rating 

max. 12 W 

max. 30 W

Voltage reduction 

50% after approx. 140 ms  50% after approx. 70 ms

PWM frequency 

7 KHz 

50 KHz

operating characteristics
Ambient temperature 

-10...+50 °C

Storage temperature 

-40...+80 °C

5. DIMENSIoNS

Size 22

Size 30

Notice
The information in these instructions is subject to change without 

notice. In no event shall ASCO Numatics be liable for technical or 

editorial errors or omissions. Neither is any liability assumed for ac-

cidental or consequential damages arising out of or in connection 

with the supply or use of the information contained herein.

Manufacturer’s Declaration according to EU Machinery Directive
We herewith declare that the version of the product described in 

this installation manual is intended to be incorporated into or as-

sembled with other machinery and that it must not be put into serv-

ice until the machinery into which it is to be incorporated has been 

declared in conformity with the provisions of the EU Directive.

Handling,  assembly  and  putting  into  service  and  all  adjustments 

and  fine-tuning  must  be  done  by  qualified,  authorised  personnel 

only.

This  product  complies  with  the  EU  Directive  on  electromagnetic 

compatibility  (as  amended).  It  is  CE  approved.  A  declaration  of 

conformity is available on request. A declaration of conformity with-

in the meaning of the EU Directive is available on request. Please 

provide the order number and serial number of the product con-

cerned.

INSTALLATION INSTRUCTIONS 

Power-save connectors, industry standard form B (11 mm), ISO 4400 / EN 175301-803, form A, 

catalogue nos. 88100934 / 88100944 (size 22),  88100945 (size 30)

GB

Reviews: