Operating Instructions Ascoline 850, MEB 4xx, 6xx
ascobloc
Gastro-Gerätebau GmbH
01156 Dresden, Grüner Weg 29
Germany
Tel.: +49 351 4533-0 Fax: +49 351 4537-339
Email:
service@ascobloc.de
MEBxxxff.doc Stan: 13.11.2018
Subject to change without notice!
7
Faults and their Rectification
7.1 Fault rectification
Faults
Cause
Remedy
Green indicator light is on,
but there is no heat
Heating, power controller, temperature limiter is
defective,
one of the phases has failed
Replace defective component
No heat at the electric
frying, grill or griddle plates
Power connection to equipment interrupted
Fuse in the customer supply has tripped
Green indicator light is on, but there is no heat
> heating element is faulty
Restore
Restore
Replace heating element
Fuse switches off
repeatedly
Wrong fuse or short-circuit
Replace
Green indicator light does
light up after switching on
Mains connection, fuse faulty, indicator light
faulty
Replace fuse
A repair may only be performed by trained, qualified specialists. Please give us the equipment number and
the type designation that are on the equipment name plate. The plate is located on the front cover A of the
equipment (see connection diagram).
7.2 Customer service
ascobloc customer service: Tel.
+49 351 4533–384
Fax
+49 351 4533–379
kundendienst@ascobloc.de