7.4 - FUNCTIONAL FEATURES

Temperature Control: ON/OFF mode
Defrost  control: interval cycles by Electric Heating or hot-gas /
reverse cycle
Measurement range: PTC: -50...99 °C / -58 ... 99 °F; 
NTC: -50...99 °C / -58...99 °F
Display resolution: 1 ° or 0,1° (in range -9.9 ..9.9 °)
Overall accuracy: +/- (0,5 % fs + 1 digit)
Sampling rate: 130 ms.
Display: 2 Digit  Red h 54 mm
Software class and structure : Class A
Compliance: ECC directive 2004/108/CE (EN55022: class B;
EN61000-4-2: 8KV air, 4KV cont.; EN61000-4-3: 10V/m; EN61000-
4-4: 2KV supply, inputs, outputs; EN61000-4-5: supply 2KV com.
mode, 1 KV\ diff. mode; EN61000-4-6: 3V),  2006/95/CE (EN
60730-1, EN 60730-2-7, EN 60730-2-9)
Approvals: ENEC (Lic.n. 00161); C-UL (file n. E212227)

7.5 - INSTRUMENT ORDERING CODE

DISPLAY AND CONTROL UNIT
TLB55  

(standard instrument)

TLB55S 

(instrument with Sensitive Touch keyboard

 

)

a b c d e f g h ii jj k

a : OUT1
Y

 =  Yes

b : OUT2
Y

 =  Yes

-

 = No

c : OUT3

= Yes

-

 = No

d : OUT4

= Yes

-

 = No

e : BUZZER

= Buzzer

-

 = (No)

f : MAIN VOLTAGE ALARMS
-

 = No

V

 = Yes

g, h : RESERVED CODE
ii, jj  : SPECIAL CODES
k : SPECIAL VERSIONS

SUPPLY AND OUTPUTS UNIT (SLAVE)
BSLB4  a b c d e f gg

a : POWER SUPPLY
H

 = 100...240 VAC

b : OUTPUT OUT1
R

 =  Relay (SPST-NO 16 A)

-

 = No

c : OUTPUT OUT2
R

 =  Relay (SPDT 8A)

-

 = No

d : OUTPUT OUT3
R

 =  Relay (SPST-NO 5A)

-

 = No

e : OUTPUT OUT4
R

 =  Relay (SPST-NO 5A)

-

 = No

f : MAIN VOLTAGE ALARMS
-

 = No

V

 = Yes

gg : SPECIAL CODES

CABLE DISPLAY-SLAVE
TLBCA aa bb

aa : LENGHT
01 = 

1 m

03 = 

3 m

bb : SPECIAL CODES

KEYBOARD
TLBTA aa bb

aa : CABLE

-- = Standard (1m)

bb : SPECIAL CODES

ASCON TECNOLOGIC - TLB55

 

- OPERATING INSTRUCTIONS - Vr. 04 - 02/12 - ISTR-MTLB55ENG04 - PAG. 11

Summary of Contents for TLB 55

Page 1: ...NS 4 9 EVAPORATOR FANS CONTROL 4 8 MANUAL DEFROST 4 7 DEFROST CONTROL 4 6 COMPRESSOR PROTECTION FUNCTION AND DELAY AT POWER ON 4 5 CONTINUOUS CYCLE FUNCTION 4 4 TEMPERATURE CONTROL 4 3 OUTPUTS CONFIGU...

Page 2: ...been selected press the P and the code that identifies the first parameter in the selected group will be visualised Again using the UP and DOWN keys the desired parameter can be selected and pressing...

Page 3: ...rules are respected also after the instrument installation if necessary using proper filters Whenever a failure or a malfunction of the device may cause dangerous situations for persons thing or anima...

Page 4: ...a contact that is normally closed and open when the alarm sounds An to control an alarm with a memory function through a contact that is normally closed and open when the alarm sounds see alarm memor...

Page 5: ...n cycle is set by the parameter dE If instead the evaporator probe is used parameter EP on the defrosting takes place when the temperature measured by the probe exceeds the temperature set in the para...

Page 6: ...output to be activated in alarm status and that they remain activated even when the alarm has ceased see par 4 9 5 Disablement recognition of memorised alarm can only be carried out manually by press...

Page 7: ...is active see selecting active set point 9 Signalling of external alarm with disablement of all the control outputs with contact normally open on closing the digital input 1 and after the ti time all...

Page 8: ...ters available on the instrument Some of them may not be present because depend on the model type of instrument Gruppo SP parametri relativi al Set Point 99 LS 99 Maximum Set Point HS 7 50 58 HS Minim...

Page 9: ...rature alarms Type Ab Absolute dE Relative to Set Ay 46 Note Def Range Description Par 3 oF 99 min Alarm delay with open door oA 54 oF oF 99 hrs Temperature alarms delay after continuous cycle cA 53 6...

Page 10: ...t be shipped to ASCONTECNOLOGIC with a detailed description of the faults found without any fees or charge for ASCONTECNOLOGIC except in the event of alternative agreements 7 TECHNICAL DATA 7 1 ELECTR...

Page 11: ...2 9 Approvals ENEC Lic n 00161 C UL file n E212227 7 5 INSTRUMENT ORDERING CODE DISPLAY AND CONTROL UNIT TLB55 standard instrument TLB55S instrument with Sensitive Touch keyboard a b c d e f g h ii jj...

Reviews: