AD2 bus configuration
Depending on the line length 1 or 2 terminals can be connected on each AD2 inter-
face. In this connection the Pocket Adapter (PA) and the DECT radio unit are also
considered as terminals. The following requirements apply with regard to the bus
length to ensure that the maximum permissible signal delay is not exceeded:
Tab. 51
AD2 bus length and number of terminals
Fig. 59
AD2 bus
Notes
The total length of the cables from the PBX to the system terminal must
not be less than 10 m.
Number of termi-
nals
Total length AD2 bus
Distance between the 1st and 2nd connection
point (excl. connection cord)
1
A: max 1200 m
–
2
B: max. 700 m or 1200 m
1)
1)
For 1200 m none of the terminals must be of the type Office 20, Office 30 or Office 40.
C: max. 10 m